8 For Professional Technical Support call 1-844-242-2475
INSTALLATION
Flexible pipe is prohibited on suction pipe (inlet pipe).Unions or hose couplings can be installed near pump to facilitate
removal for servicing or storage. A rubber hose installed between the water system and the house piping will reduce
the noise transmitted to the house.
1. Installing Piping In Well
CAUTION: Dry-fit entire assembly to ensure proper fit before gluing or taping parts. Follow all proper gluing
procedures as specified by the glue manufacturer. Always glue in a vertical direction whenever possible to prevent
glue from dripping inside pipe or fittings Use pipe tape and pipe paste compound on all male threads. Tighten with
wrench to a snug fit and add another 1/4 turn to ensure proper seal.
For Cased well Installation
1. Connect
1-1/4in.Brass Foot Valve
to
1-1/4in. PVC MPT×S
Male Adapter
. Cement adapter to
1-1/4 in. PVC rigid Pipe
.
All connections must be air- and water-tight for pump to
operate correctly. (Fig 1)
2. Install
well seal
over 1-1/4 in. PVC rigid Pipe and into
well
casing
. Position the foot valve 5 feet above bottom of well and
at least 10 feet below the well’s water level. (Fig 2)
3. Cement
1-1/4in. PVC MPT×S Male Adapter
at the top of
the Pipe
.
Install
1-1/4in. PVC TEE FPT×FPT×FPT
to the
adapter. One end of port install another
1-1/4in. PVC MPT×S
Male Adapter
. Add sections of pipe to reach the adapter.
(Fig 3)