2 For Professional Technical Support call 1-844-242-2475
PERFORMANCE
Model
HP
GPH of Water @ Total Feet Of Lift
Max.
Lift
0 ft.
5 ft.
10 ft.
15 ft.
20 ft.
25 ft.
SPI03302K
1/3
4000
3800
3200
2800
2200
1100
26
SPI05002K
1/2
4620
4330
3920
3285
2515
1320
26
SPI07502K
3/4
5200
4500
4080
3480
2820
1500
28
SPI10002K
1
5600
5220
4720
4320
3660
2520
32
SAFETY INSTRUCTIONS
1. Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the
presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an
explosion or fire, resulting in property damage, serious personal injury, and/or death.
2.
ALWAYS disconnect the power to the pump before servicing.
3.
Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not
disassemble the motor housing.
4.
Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water
before disconnect the power.
5.
Release all pressure and drain all water from the system before servicing any component.
6.
Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing
personal injury, and/or property damage.
7.
Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening
safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension
cord to power this pump is not permitted.
8.
Wear safety goggles at all times when working with pumps.
9.
This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved
3-conductor cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The
3-prong plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle.
Do not use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong
receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and local codes and
ordinances. All wiring should be performed by a qualified electrician.
10. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use
damaged or worn cords.
11. Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO
USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.
12. Ensure that the electrical circuit to the pump is protected by a 15 Amp fuse or circuit breaker.
13. Do not lift the pump by the power cord.
14. Know the pump and its applications, limitations, and potential hazards.
15. Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in
keeping the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in
premature failure.
16. Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand,
and debris. Disconnect the pump from the power supply before inspecting.