26 of 28
Troubleshooting
Symptom
Suggestion
Multiple zones
watering at once
Solenoids may be dirty: clean and flush solenoids to remove
debris. Possible faulty driver triac, incorrect field wiring
or broken or lost common wire in field. Check wiring and
swap faulty valve wires on the controller terminal block
with known working zones. If the same outputs are still
locked on, please contact our Customer Service team
KRX6
is not
connecting in
AP MODE
Ensure mobile data is switched off
Fuse keeps
blowing
The 1amp glass fuse is installed in the controller to protect the
board from being damaged as a result of something wrong in the
field wiring (this is the wiring from the solenoid to the controller).
If your fuse has blown, check that your wiring on each
station is in tack and not damaged in any way. If your
fuse is continuously blowing, remove all wires from
your stations. Reconnect each station one at a time to
help determine which station is causing the fault.
Our irrigation controllers use a 5mm x 20mm 1amp glass fuse