31
Visual Basic
TRIG_Trigger_Route (ByVal source As Long, ByVal dest As Long, ByVal halfway As Long)
As Integer
Parameters
source
Source of trigger routing. It can be one of the following values
Available value
Description
PXI_TRIG_VAL_SMB
SMB connector on the faceplate
PXI_TRIG_VAL_SOFT
Software-generated trigger signal
PXI_TRIG_VAL_TRIG0
PXI trigger bus #0
PXI_TRIG_VAL_TRIG1
PXI trigger bus #1
PXI_TRIG_VAL_TRIG2
PXI trigger bus #2
PXI_TRIG_VAL_TRIG3
PXI trigger bus #3
PXI_TRIG_VAL_TRIG4
PXI trigger bus #4
PXI_TRIG_VAL_TRIG5
PXI trigger bus #5
PXI_TRIG_VAL_TRIG6
PXI trigger bus #6
PXI_TRIG_VAL_TRIG7
PXI trigger bus #7
dest
Destination of trigger routing. It can be one of the following values.
Available value
Description
PXI_TRIG_VAL_SMB
SMB connector on the faceplate
PXI_TRIG_VAL_TRIG0
PXI trigger bus #0
PXI_TRIG_VAL_TRIG1
PXI trigger bus #1
PXI_TRIG_VAL_TRIG2
PXI trigger bus #2
PXI_TRIG_VAL_TRIG3
PXI trigger bus #3
PXI_TRIG_VAL_TRIG4
PXI trigger bus #4
PXI_TRIG_VAL_TRIG5
PXI trigger bus #5
PXI_TRIG_VAL_TRIG6
PXI trigger bus #6
PXI_TRIG_VAL_TRIG7
PXI trigger bus #7
halfway
Halfway point of trigger routing. This parameter is used only to route the software-generated
trigger signal to the SMB connector on the faceplate. In this case, the halfway should be set
as one of the trigger bus lines, otherwise as PXI_TRIG_VAL_NONE.
Available value
Description
PXI_TRIG_VAL_NONE
No halfway point
PXI_TRIG_VAL_TRIG0
PXI trigger bus #0
PXI_TRIG_VAL_TRIG1
PXI trigger bus #1
PXI_TRIG_VAL_TRIG2
PXI trigger bus #2
PXI_TRIG_VAL_TRIG3
PXI trigger bus #3
PXI_TRIG_VAL_TRIG4
PXI trigger bus #4
PXI_TRIG_VAL_TRIG5
PXI trigger bus #5
PXI_TRIG_VAL_TRIG6
PXI trigger bus #6