PCIe/PXIe-6302 |
| 26
5.2.3 Sampling Rate
When 6302 works, each sample contains the completion of an A/D conversion on all
channels, the principle is shown in Figure 22.
Figure 22 A/D conversion and sampling
The timing required for each A /D conversion is controlled by setting rate level. The
minimum sampling rate of PCIe/PXIe-6302 is 0.275 Samples/s, and the highest
sampling rate is 800 Samples/s. The actual maximum sampling rate is according to
the rate level and the number of channels added by each ADC:
��� ������ ���� =
Max Total Sample Rate
max (number of channels on any one ADC)
Among them:
��� ������ ����
:
The maximum sample rate that can be set
max (number of channels on any one ADC)
:
Maximum number of channels
added on a single ADC
Max Total Sample Rate
:
The maximum total sampling rate at the current rate
level, as shown in Table 14.
Summary of Contents for PCIe/PXIe-6302
Page 8: ...PCIe PXIe 6302 jytek com 4 Figure 3 TB 68CJ Pin Define...
Page 11: ...PCIe PXIe 6302 jytek com 7 2 3 Specification 2 3 1 Input Characteristics...
Page 14: ...PCIe PXIe 6302 jytek com 10 Table 6 Pinout defination...
Page 17: ...PCIe PXIe 6302 jytek com 13 Figure 11 Typical Noise Level 2 Figure 12 Typical Noise Level 3...
Page 18: ...PCIe PXIe 6302 jytek com 14 Figure 13 Typical Noise Level 4 Figure 14 Typical Noise Level 5...