19
Cabling the SeaOtter-2 (continued)
The drawing below shows the cable connections for the SeaOtter-2.
Step 5.
Connecting power (be sure Main Power Switch on control panel is turned off) :
• Never connect any voltage other than 115 - 120 vac to the control box.
• The best source of 120 vac is a generator (1,000 watt or higher).
• If only 220 is available use a 220 to 120vac step down transformer (1,000 watt, JWF can supply).
• If only 12 vdc is available use an 12 vdc to 120 vac inverter (1,000 watt, JWF can supply).
• For safety reasons, a ground fault outlet should be used.
SeaOtter-2
Microphone
120vac
(only)
220 vac
to
120 vac
transformer
Ground Fault
Power Source
if 120vac
if 220vac
250 ft
Umbilical
cable
Umbilical
cable
extension
12 vdc
to
120 vac
inverter
if 12 vdc
We are ready to power up the system
Buoyancy collars
(over in-line connectors)
Remote
Monitor
DVD Recorder
Summary of Contents for SeaOtter-2
Page 11: ...11 Left Blank...