No.51961
TM-H1950CG
31
Item
Test equipment
Test points
Ad justment
locations
Ad justment procedure
RGB signal
BRIGHT
adjustment
Comp onent / RGB
input card
(IF-C01COM)
Signal generator
(Sprit colour bar)
Signal distributor
S07 (RGB BRIGHT)
[SERVICE MENU]
1. Turn off the main power s witch on the rear panel.
2. Ins ert the component / RGB input card to the rear
slot.
3. Input the 3 kind signals (G:B:R, Y:Pb:Pr, Y:B-Y:R-
Y) to the each terminal of the component / RGB
input c ard.
4.
In c ase of us ing the c omposite sync hronous
signal, input the s ynchronous signal to the HD/CS
terminal only. But in c ase of using the separate
synchronous signal, input the horizontal
synchronous signal to the HD/CS terminal and
vertical s ynchronous signal to the VD terminal.
5. Select the “INPUT D” by the front panel switch.
6. Select the SIGNAL BLOCK from SERVICE MENU.
7. Select the S07 item.
8. Adjust the S07 to where the sprit c olour bar 0%
blac k component not to brightens .
9. Check it out by pressing the “DISP” switch on and
off.
RGB signal
CONT RAST
adjustment
Comp onent / RGB
input card
(IF-C01COM)
Signal generator
(Sprit colour bar)
Signal distributor
Oscillo-scope
TP-47G
TP-E(
#
)
[CRT SOCKET
PWB]
S08 (RGB
CONT RAST)
[SERVICE MENU]
1. Turn off the main power s witch on the rear panel.
2. Ins ert the component / RGB input card to the rear
slot.
3. Input the 3 kind signals (G:B:R, Y:Pb:Pr, Y:B-Y:R-
Y) to the each terminal of the component / RGB
input c ard.
4.
In c ase of us ing the c omposite sync hronous
signal, input the s ynchronous signal to the HD/CS
terminal only. But in c ase of using the separate
synchronous signal, input the horizontal
synchronous signal to the HD/CS terminal and
vertical s ynchronous signal to the VD terminal.
5. Select the “INPUT D” by the front panel switch.
6. Connect the oscillo-scope probe to TP-47G and
TP-E(
#
).
7. Select the SIGNAL BLOCK from SERVICE MENU.
8. Select the S08 item.
9. Adjust the S08 to become the voltage different
between 75% white and blue to
37V
±
±
±
±
2Vp-p
as
shown in figure.
V
75-BL
=(37
±
±
±
±
2)V(p-p)
BL
B
R
Mg
G
Cy
Y
W
75%
WHITE