No.51961
TM-H1950CG
29
Item
Test equipment
Test points
Ad justment
locations
Ad justment procedure
PAL CHROMA
Saturatio n
adjustment
Signal generator
(Full colour bar)
Oscillo-scope
TP-47B
TP-E(
#
)
[CRT SOCKET
PWB]
S03(PAL CHROMA)
[SERVICE MENU]
1. Input a PAL full colour bar signal.
2. Connect the oscillo-scope probe to TP-47B and
TP-E(
#
).
3. Select the SIGNAL BLOCK mode from <BLOCK
SELECT> screen.
4. Select the S03 item.
5. Adjust the S03 to become the voltage different
between 75% white and blue to
0V
±
±
±
±
2Vp-p
as
shown in figure.
PAL PHASE
Saturatio n
adjustment
Signal generator
(Full colour bar)
S11(PAL PHASE)
[SERVICE MENU]
1. Select the SIGNAL BLOCK mode from <BLOCK
SELECT> screen.
2. Select the S11 item.
3. Confirm that the value is 062. If differ, correctly
set the value to 062.
NT SC 3.58
CHROMA
Saturatio n
adjustment
Signal generator
(Full colour bar)
Oscillo-scope
TP-47B
TP-E(
#
)
[CRT SOCKET
PWB]
S04
(NT SC CHROMA)
[SERVICE MENU]
1. Input a NTSC 3.58 full colour bar signal.
2. Connect the oscillo-scope probe to TP-47B and
TP-E(
#
).
3. Select the SIGNAL BLOCK mode from <BLOCK
SELECT> screen.
4. Select the S04 item.
5. Adjust the S04 to become the voltage different
between 75% white and blue to
0V
±
±
±
±
2Vp-p
as
shown in figure.
0V
±
±
±
±
2V
BL
B
R
Mg
G
Cy
Y
W
75%
0V
±
±
±
±
2V
BL
B
R
Mg
G
Cy
Y
W
75%