background image

2

Dear Customer,

This apparatus is in conformance with the valid 
European directives and standards regarding 
electromagnetic compatibility and electrical safety.

European representative of JVC KENWOOD 
Corporation is:
JVC Technical Services Europe GmbH
Konrad-Adenauer-Allee 1-11
61118 Bad Vilbel
Germany

o

Stop using this product if any of the 
abnormalities below is detected

Otherwise, it may cause fire or electric shock.

When smoke, unusual odor, or other abnormal 
symptoms are found.

When the unit is not functioning properly, such as 
when there is no image on the display or no sound.

When water or other foreign object gets into the unit.

When the cabinet is damaged from dropping.

When the power cable is damaged. (Exposure or 
breaking of the cable core, etc.)

If any of the above occurs, turn off the power 
immediately, and unplug the power cable from the 
outlet.
If smoke is detected, confirm that smoke has stopped 
emitting before sending the product to the dealer for 
repair.
You must not attempt to repair the product on your own. 
Doing so may be dangerous.

o

Do not block the ventilation holes

Blocking the ventilation holes may cause heat to trap 
inside the unit and result in fire.

o

Do not dismantle or modify the product

The product may malfunction or break down.

o

Do not damage the power cable

Damaging the power cable may cause fire or electric 
shock.

Do not alter the power cable.

Do not bend, twist, or pull the cable by force.

Do not place equipment or other heavy objects on 
the power cable.

Do not place the power cable near a heating 
equipment.

o

Do not place the product on an unstable surface.

Do not place the product on an unstable platform or 
inclined surface. The unit may fall off, causing it to 
malfunction or break down.

o

Do not place heavy objects on the product

If heavy objects or those with a bigger size than the unit 
are placed on it, the product may lose its balance and 
fall off, thus causing injuries.

o

Unplug the power cable if the product is not to 
be used for a long time

For reasons of safety and energy conservation, unplug 
the power cable if you are not using it again soon.

o

Do not pull the cord when unplugging the power 
cable

Pulling the power cable at the cord may damage it, 
causing fire or electric shock. To unplug, pull out by 
holding the plug.

o

Do not unplug power cable with wet hands

Doing so may cause electric shock.

o

Unplug the power cable and disconnect all 
cables before moving the unit

Moving the unit with the cables connected may 
damage the cables, causing fire or electric shock.

Locations of Storage and Use

o

Do not place this product at the following 
locations.

Doing so may cause the product to malfunction or 
break down.

Hot or cold places beyond the allowable operating 
temperature range (10 °C to 35 °C)

Places that emit a strong magnetic field, such as 
near transformers and motors

Places near devices that emit radio waves, such as 
transceivers and mobile phones

Places with considerable dust and sand

Places subject to strong vibrations

Places where water droplets may be formed, such as 
window sides

Places that emit radiation, X-rays, and corrosive 
gases

Handling Precautions

o

Do not stack the devices on one another during 
use.

Heat and noise from the other units may cause the 
product to malfunction or break down, and result in fire.

o

Do not block the ventilation holes

Doing so may cause heat to trap inside the unit and 
result in fire. Do not use this product by laying it down 
sideways, upside down, or at an angle.

o

Do not insert objects into this unit.

Metallic or other flammable objects that get into this 
unit, such as through the ventilation holes, may result 
in fire or electric shock.

Maintenance

o

To clean this product, wipe it with a soft rag.

Wiping using thinner or benzene may cause the surface 
to melt or fog. When the surface is extremely dirty, wipe 
using a cloth that is dipped into a neutral detergent 
diluted with water, followed by wiping with a dry cloth.

Energy Conservation

o

For reasons of safety and energy conservation, 
unplug the power cable if you are not using the 
product again soon.

Safety Precautions

Precautions for Proper Use

PK-EXT40TG_EN.book  Page 2  Tuesday, April 23, 2013  1:53 PM

Summary of Contents for PK-EXT40T

Page 1: ... read through this INSTRUCTIONS in advance to ensure proper use of the product Also please make sure that you read through the Safety Precautions to learn how to use this product safely After reading keep this manual in a safe place for future reference To request for installation please contact our dealer For Customer use Enter below the serial No which is located on the rear side of the cabinet ...

Page 2: ...for a long time For reasons of safety and energy conservation unplug the power cable if you are not using it again soon oDo not pull the cord when unplugging the power cable Pulling the power cable at the cord may damage it causing fire or electric shock To unplug pull out by holding the plug oDo not unplug power cable with wet hands Doing so may cause electric shock oUnplug the power cable and di...

Page 3: ...nces in large scale fixed installations and can be used in the following environments Controlled EMC environment for example purpose built broadcasting or recording studio and the rural outdoors environment far away from railways transmitters overhead power lines etc In order to keep the best performance and furthermore for electromagnetic compatibility we recommend to use the cables not exceeding...

Page 4: ...ccording to Installation and Connection 2 Turn on the power for the optical transmitter and optical receiver units After connection is established the AOptB Status LED on the optical transmitter and optical receiver units will light up Caution If AOptB does not light up check for the following Improper connection of the connectors Check the connection Dirt on the connector terminal surface Clean t...

Page 5: ...5 PK EXT40TG_EN book Page 5 Tuesday April 23 2013 1 53 PM ...

Page 6: ...ded Terminal DVI D x 4 MPO x 1 Transfer rate Up to 40 Gbps Maximum resolution supported 4096 x 2400 Attachments Accessories INSTRUCTIONS 1 Warranty Card 1 Power cable 1 5 m 2 pcs The specifications and appearance of this unit may be modified for improvement without prior notice PK EXT40TG is intended for use in large scale fixed installations Specifications PK EXT40TG_EN book Page 6 Tuesday April ...

Page 7: ...ネ ッ ト ワ ー ク 設 定 Optical DVI Transmitter PK EXT40T 取扱説明書 PK EXT40T book Page 1 Tuesday April 23 2013 1 43 PM ...

Page 8: ...売店に修理を依頼してください お客様ご自身が修理することは危険です 絶 対にやめてください o通風孔をふさがない 通風孔をふさぐと 内部に熱がこもり火災の 原因となります o分解 改造しない 破損や故障の原因となります o電源コードを傷つけない 電源コードを傷つけると 火災や感電の原因 となります 電源コードを加工しない 無理に曲げたり ねじったり 引っ張っ たりしない 電源コードの上に機器本体や重いもの をのせない 電源コードを熱器具に近づけない 安全上のご注意 絵表示について この表示 文字含む を無視して 誤った取り扱いをすると 人が死亡または重傷を負う可能 性が想定される内容を示しています この表示 文字含む を無視して 誤った取り扱いをすると 人が傷害を負ったり 物的損害 の発生が想定される内容を示しています 䢇 注意 警告を含む が必要な ことを示す記号 䢇 してはいけない行為...

Page 9: ...がつき 火災や感電の原因となることがあります 保管および使用場所 o次のような場所に置かない 誤動作や故障原因になります 許容動作温度 10 35 範囲外の 暑いとこ ろや寒いところ 変圧器やモーターなど強い磁気を発生するところ トランシーバーや携帯電話など電波を発生する機 器の近く ほこりや砂の多いところ 振動の激しいところ 窓ぎわなど水滴の発生しやすいところ 放射線や X 線 および腐食性ガスの発生するとこ ろ 取り扱いについて o機器を重ねて使用しない お互いの熱やノイズの影響で誤動作したり故障し たり 火災の原因となることがあります o通風孔をふさがない 通風孔をふさぐと 内部の熱が逃げないので火災の 原因となります 本機を横倒し 逆さま あお向け の状態でご使用しないでください o内部に物を入れない 通風孔などから 金属類や燃えやすいものなどが入 れると火災や感電の原因となります...

Page 10: ...インジケーター Dual Link の信号がある場合に点灯します E OPT 光出力端子 12 心の MPO コネクターケーブルを接続します F DVI D 入力端子 1 4 映像信号の入力端子です 1 4 系統の Dual Link DVI D 信号を接続します フロントパネルの Status LED とチャンネル番号はリンクします G 電源入力端子 付属の電源コードを接続します AC100V に対応した電源を接続します 各部の名称とはたらき 前面 Optical DVI Extender PK EXT40T Opt 1 2 3 4 Sink Source Dual AB C D 背面 OPT DVI D Dual link 100 l 240 VAC 1 3 2 4 E F G PK EXT40T book Page 4 Tuesday April 23 2013 1 43 PM ...

Page 11: ... 1 設置 接続 に従って設置する 2 光送信ユニットおよび光受信ユニットの電源を 入れる 接続が確認されると光送信ユニットおよび光受信 ユニットの Status LED の AOptB が点灯します ご注意 AOptB が点灯しない場合は 下記の項目をご確認願いま す コネクター部の接続が不十分 接続を確認してください コネクター端子面へのゴミ付着 端子面の清掃をしてください 光ファイバーケーブルの断線 別のケーブルで確認してください 3 映像信号源の電源を入れる 光送信ユニットおよび光受信ユニットの Status LED の ASourceB が点灯します 4 プロジェクターの電源を入れる 光送信ユニットおよび光受信ユニットの Status LED の ASinkB が点灯します モニターに表示されます メモ 環境温度 送風などにより機器の温度が著しく上昇 しないようにすることにより ...

Page 12: ...Transmitter PK EXT40T 電源 AC 100 V 消費電力 20 W 許容動作温度範囲 10 35 外形寸法 213 mm x 42 mm x 330 mm 幅 x 高さ x 奥行き 質量 2 06 kg 3 4 kg 梱包 添付物含む 端子 DVI D x 4 MPO x 1 転送レート 最大 40 Gbps 最大対応解像度 4096 x 2400 添付物 付属品 取扱説明書 1 保証書 1 電源コード 1 5m 1 本 T 本機の仕様および外観は 改善のため予告なく変更することがあります T 本機は JIS C61000 3 2 適合品 です 仕様 PK EXT40T book Page 6 Tuesday April 23 2013 1 43 PM ...