E54
@ @ @ @ @ @
6. Menu screen settings (continued)
PROCESS (1/3) screen (continued)
Menu item
GAMMA
LEVEL
MASTER BLACK
Function/variable range
Used to set whether the gamma curve to determine the
reproduction of black is to be set using the standard value
or available for change.
NORMAL: the gamma curve is set using the standard
value (0.45)
ADJUST: set when changing the gamma curve
The gamma curve can be adjusted only when GAMMA is
set to ADJUST.
Increase the number:
improves the reproduction of
black. However, the reproduction
quality of bright areas becomes
lower.
Decrease the number: improves the reproduction of
bright areas. However, the repro-
duction quality of black becomes
lower.
[Variable range: 0.35 ~ 1.00 (21 steps)]
Used to adjust the pedestal level (master black), which is
the standard black during lens cap. To view black areas,
increase the pedestal level to brighten the entire screen.
Increase the pedestal level:
increase the number
Decrease the pedestal level: decrease the number
[Variable range: –99 ~ 99]
Default value
NORMAL
0.45
0