(No.MA475<Rev.001>)1-23
4.6.2 Mechanical Error Detail Codes
Condition
Details
Error Code
Detail Code
Disc Loading Error
(1) B1 Time Out
After detecting SW1=L, it does not become SW2=L
09
0011
(2) B2 Time Out
After detecting SW2=H, it does not become SW2=L
09
0012
(3) C1 Time Out
After detecting SW2=L, it does not become SW2=H
09
0013
Eject Error
(1) B1 Time Out
After detecting SW2=H, it does not become SW2=L
01
0021
(2) C2 Time Out
After detecting SW2=L, it does not become SW2=H
01
0022
(3) B2 Time Out
After detecting SW1=L, it does not become SW2=L
immediately after RESET and so on.
01
0023
(4) D0 Panel Close
Disc can not be ejected due to closed panel.
01
0024
Forced Eject Error
(1) E1 Error
SW1=H, SW2=L detected from NO DISC
01
0041
(2) E2 Error
Detected SW1=L after RESET, and then detected SW1=H
01
0042
(3) E3 Error
Detected SW1=H after RESET
01
0043
(4) E4 Error
Detected SW1=H after SW1=L
01
0044
(5) E5 Error
Detected SW1=H after SW2=H
→
L
01
0045
(6) E6 Error
Time Out for Loading after RESET
01
0046
(7) E7 Error
Detected SW1=H after SW2=H
→
L
→
H
01
0047
(8) E8 Error
Eject Key input while the procedure is not completed after
01
0048
Forced Eject execution
(9) E9 Error
Eject Key input during Disc is on the way and not completed
01
0049
Loading Waiting Error
(1) SW1=H or NO DISC
detection before Loading
Motor activation during
Disc is waiting at the
waiting location.
Disc is removed or NO DISC detection condition
09
0031
(2) SW2=L before Loading
Motor activation during
Disc is waiting at the
waiting location.
Disc is inserted
09
0032