(No.MA471<Rev.005>)1-13
3.2.6 Removing the slide cam (L) (See Fig.11 to 13)
• Remove the MECHANISM CONTROL BOARD assembly, top
cover and mechanism section.
(1) From the top side of the mecha frame, remove the screw
F
attaching the cam cover. (See Fig.11.)
(2) Take out the cam cover from mecha frame in an upward
direction. (See Fig.11.)
Fig.11
(3) Take out the slide cam (L) in the direction of the arrow.
(See Fig.12.)
Fig.12
Reference:
When attaching the slide cam (L), apply grease to the
section
h
. (See Fig.13.)
Fig.13
3.2.7 Removing the F.lock lever and slide cam (R) (See
Fig.14 and 15)
• Remove the MECHANISM CONTROL BOARD assembly, top
cover and mechanism section.
(1) From the top side of the mecha frame, take out the slide
cam (R) assembly in an upward direction. (See Fig.14.)
(2) Rotate the F.lock lever in the direction of the arrow 1, and
then take out the direction of the arrow 2. (See Fig.14.)
Fig.14
Mecha frame
Cam cover
F
Mecha frame
Slide cam(L)
Slide cam(L)
Slide cam(L)
h
h
h
h
h
h
h
h
h
h
h
h
h
h
Mecha frame
Link arm
F.lock lever
2
1
Slide cam(R) assembly
Summary of Contents for KW-XG56TU
Page 27: ... No MA471 Rev 005 1 27 ...