1-26 (No.MA473<Rev.002>)
Note: "**" of the above error code is the number of the pulse counts at the time of the error outbreak.
4.10 Running mode
* Cancellation of running1,2 and 3 : Press the [EJECT] key
* In running 1,2 and 3 cancellation, a door does not stop at the position and moves to a panel position.
* Cancellation of running4 to 9 : Press the [POWER] key
* The number of count and an error cord are displayed in running.
Playback contents in a running mode
• CD
The first track is played for 30 seconds.
→
The last track is played for 30 seconds.
(The last track is played in the case of less than till the last for 30 seconds.)
• DVD
2layer disc (Pit disc)
Title 1 (the L0 layer internal circumference) is played for 30 seconds.
→
Title 12 (L0 layer circumference) is played for 30 seconds.
→
Title 24 (L1layer internal circumference) is played for 30 seconds.
2layer disc (Recordable disc)
Title 1 (the L0 layer internal circumference) is played for 30 seconds.
→
Title 13 (L0 layer circumference) is played for 30 seconds.
→
Title 24 (L1layer internal circumference) is played for 30 seconds.
1layer disc
First chapter of title 1 is played for 30 seconds.
→
The last chapter of title 1 is played for 30 seconds.
Detail
Error code
It is time-out during movement to the closed position.
0B**11
It is time-out during 5 degrees tilt movement.(open direction)
0B**20
It is time-out during 5 degrees tilt movement.(close direction)
0B**21
It is time-out during 10 degrees tilt movement.(open direction)
0B**30
It is time-out during 10 degrees tilt movement.(close direction)
0B**31
It is time-out during 15 degrees tilt movement.(open direction)
0B**40
It is time-out during 15 degrees tilt movement.(close direction)
0B**41
It is time-out during 20 degrees tilt movement.(open direction)
0B**50
It is time-out during 20 degrees tilt movement.(close direction)
0B**51
It is time-out during 25 degrees tilt movement.(open direction)
0B**60
It is time-out during 25 degrees tilt movement.(close direction)
0B**61
It is time-out during 30 degrees tilt movement.(open direction)
0B**70
It is time-out during 30 degrees tilt movement.(close direction)
0B**71
It is time-out during movement to the open position.
0B**80
It is position error during close position stop.
0C0011
It is position error during 5 degree tilt position stop.
0C0020
It is position error during 10 degree tilt position stop.
0C0030
It is position error during 15 degree tilt position stop.
0C0040
It is position error during 20 degree tilt position stop.
0C0050
It is position error during 25 degree tilt position stop.
0C0060
It is position error during 30 degree tilt position stop.
0C0070
It is position error during open position stop.
0C0080
Detect abnormal voltage (1)
F3**XY
Detect abnormal voltage (2)
F5**XY
Detect abnormal voltage (3)
F7**XY
Detect abnormal voltage (4)
F8**XY
Indication
Explanation
Operation contents of 1 cycle
In mecha error In disc error
RUNNING1 MECHA Door mecha running 1
Panel close
↔
Panel open
-
-
RUNNING2 MECHA Door mecha running 2
Panel close
→
5 degrees
→
10 degrees
→
15 degrees
→
20 degrees
→
25 degrees
→
30 degrees
→
anel open
-
-
RUNNING3 MECHA Door mecha running 3
Panel
→
close
→
5 degrees
→
····
→
30 degrees
→
····
→
5 de-
grees
→
Panel close
-
-
RUNNING4 DVD
DVD+Door mecha running1 Loading
→
Eject
→
Wait for 5 Door open/close
Stop
-
RUNNING5 DVD
DVD+Door mecha running2 Loading
→
Eject
→
Wait for 5 Door open/close
Retry
-
RUNNING6 DVD
DVD+Door mecha running3 Loading
→
Playback
→
Eject
→
Wait for 5 Door open/close
Stop
Stop
RUNNING7 DVD
DVD+Door mecha running4 Loading
→
Playback
→
Eject
→
Wait for 5 Door open/close
Retry
Stop
RUNNING8 DVD
DVD+Door mecha running5 Loading
→
Playback
→
Eject
→
Wait for 5 Door open/close
Stop
Retry
RUNNING9 DVD
DVD+Door mecha running6 Loading
→
Playback
→
Eject
→
Wait for 5 Door open/close
Retry
Retry
Summary of Contents for KW-ADV793J