1-13
KS-LX200R
Adjustment method
1.Digital osclloscope(100MHz)
2.Frequency Counter meter
3.Electric voltmeter
4.Wow & flutter meter
5.Test Tapes
VT724
VT739
VT712
VT703
6.Torque gauge
Measuring conditions(Amplifier section)
Power supply voltage
Load impedance
Line out
Standard volume position
Balance and Bass,Treble volume .Fader
:Center(Indication"0")
Loudness,Dolby NR,Sound,Cruise:Off
Volume position is about 2V at speaker output with
following conditions.Playback the test tape VT721.
AM mode 999kHz/62dB,INT/400Hz,30%
modulation signal on receiving.
FM mono mode 97.9MHz/66dB,INT/400Hz,22.5kHz
deviation pilot off mono.
FM stereo mode 1kHz,67.5kHz dev. pilot7.5kHz dev.
Output level 0dB(1 V,50 /open terminal).
for DOLBY level measurement
For playback frequency measurement
For wow flutter & tape speed measurement
For head azimuth measurement
Cassette type for CTG-N
(mechanism adjustment)
DC14.4V(10.5~16V)
4 (2Speakers connection)
20k
Tuner section
BAND STEP
FM : 100kHz (Seek), 50kHz (Manual)
AM : 9kHz step
DUMMY LOAD
Exclusive dummy load should be used for AM
and FM dummy load,there is a loss of 6dB
between SSG output and antenna input. The
loss of 6dB need not be considered since
direct reading of figures are applied in this
working standard.
Arrangement of Adjusting
Cassette Mechanism Section
Preset Memory Initialization
Preset Memory
Band
M1
87.5
153
M2
89.9
216
M3
97.9
603
M4
105.9
999
M5
108.0
1404
M6
87.5
1620
FM(MHz)
AM(kHz)
Azimuth screw
(Forward side)
Azimuth screw
(Reverse side)
Playback head
Tape speed adjust
Capstan motor
Cassette mechanism
(Surface)
Test Instruments reqired for adjustment
Summary of Contents for KS-LX200R
Page 40: ...KS LX200R 3 2 MEMO ...