•By applying 3VDC to turn on the supply, you are now able to troubleshoot
the supply in a Stand Alone Fully Powered Condition. This eliminates
shorts caused by other PWBs.
•Check the circuits listed in the order specified to find PWB trouble.
•If a Circuit is found to be unsatisfactorily functional, use the
troubleshooting procedures in the sections that will follow to aid in testing
the specific circuit.
•The
SSR-9001A-M2 PWBs
Switching Circuits Operate in Standby Mode,
therefore it is possible test many of these circuits by only applying AC line
voltage. Although, Standby Mode will not provide full Output Voltage
from the Transformer Secondary.
• B1 Power On at the correct Voltage is a good sign that the PWB has no
defects.
•Refer to SWITCH CIRCUIT REVIEW section for assistance identifying
the circuits and their functions.