![JVC I'Art AV-27MF36 Power Supply Training Download Page 88](http://html.mh-extra.com/html/jvc/iart-av-27mf36/iart-av-27mf36_power-supply-training_177055088.webp)
FUNCTION CHECK PROCEDURE
CHECK STANDBY CIRCUITS
TELEVISION
AV-48P776/H
SSR-9001A-M2 PWB
Reference YA318 Schematic
CHECK CIRCUITS
1. F905
Surge Protection
2. D901 and C907
Main rectifier
3. IC911
Switching Regulator
4.
D911, R911 and C914
Startup
5. T921
Switching Transformer
6.
R923, C903 and R920
Current Feedback
7. FR915 and D912
Run DC
8. PC921
Photo Coupler