1-6
1.6
EMERGENCY DISPLAY FUNCTION
This unit has a function for storing the history of the past two
emergencies (EMG) and displaying them on each FDP. With the
status of the VCR and mechanism at the moment an emergency
occurred can also be confirmed.
Notes:
• The emergency detail display
1
2
show the information
on the latest emergency.
It becomes “ – – : – – : – –” when there is no latest emer-
gency record.
• When using the Jig RCU, set its custom code to match
the custom code of the VCR.
FDP display switching
FDP display 0 : 00 :
00
Emergency detail display
2
Emergency detail display
1
Emergency content display
(E:Latest:Previous)
Normal display
*
1:
*
2 :
3 4
E:
**
:
**
*
5:
*
6 :
*
7
Fig. 1-6-1 Jig RCU [PTU94023B]
Note:
• For the emergency content, see “1.6.3 Emergency con-
tent description”.
(2) Transmit the code “59” from the Jig RCU again.
The FDP shows the emergency detail information
1
in the
form of “
*
1 :
*
2 :
3 4
”.
*
1
: Deck operation mode at the moment of emergency
*
2
: Mechanism operation mode at the moment of emer-
gency
3 –
: Mechanism sensor information at the moment of
emergency
– 4
:
Mechanism mode position at the moment of emer-
gency
Note:
• For the emergency detail information 1 , see “1.6.4 Emer-
gency detail information
1
”.
(3) Transmit the code “59” from the Jig RCU once again.
The FDP shows the emergency detail information
2
in the
form of “
*
5
:
*
6
:
*
7
”.
*
5
: Type of the cassette tape in use
1
.
*
6
: Winding position of the cassette tape in use
*
7
: Type of the cassette tape in use
2
(Winding area)
Note:
• For the emergency detail information
2
, see “1.6.5 Emer-
gency detail information
2
”.
(4) Transmit the code “59” from the Jig RCU once again to re-
set the display.
1.6.2
Clearing the emergency history
(1) Display the emergency history.
(2) Transmit the code “36” from the Jig RCU.
(3) Reset the emergency display.
Example 1 E : 01 :
03
Previous emergency
Latest emergency
No emergency record
Example 2
E : – – :
– –
1.6.1
Displaying the emergency information
(1) Transmit the code “59” from the Jig RCU.
The FDP shows the emergency content in the form of
“E:
**
:
* *
”.
INITIAL MODE
DATA CODE
CUSTOM CODE
43: A
CODE
53: B
CODE
[Data transmitting method]
Depress the “ ” ( 3 ) button
after the data code is set.
Jig RCU
(Y292-03e)
Summary of Contents for HR-S6700MS