1-16 (No.YD014)
4.3.2.2
EE Y level
(1) Observe the V OUT waveform at the measuring point (D).
(2) Set the VCR to the EVR mode by transmitting the code (F1)
from the Jig RCU.
(3) Set the EVR address to (F2) by transmitting the code (F3)
from the Jig RCU.
(4) Transmit the code (F4) from the Jig RCU to adjust so that
the Y level of the V OUT waveform becomes the specified
value (G).
(5) Release the EVR mode of the VCR by transmitting the
code (F5) from the Jig RCU again. (When the EVR mode
is released, the adjusted data is memorized.)
Fig.4-3c EE Y level
4.3.2.3
EE composite burst level
(1) Observe the V OUT waveform at the measuring point (D).
(2) Set the VCR to the EVR mode by transmitting the code (F1)
from the Jig RCU.
(3) Set the EVR address to (F2) by transmitting the code (F3)
from the Jig RCU.
(4) Transmit the code (F4) from the Jig RCU to adjust so that
the burst level of the V OUT waveform becomes the spec-
ified value (G).
(5) Release the EVR mode of the VCR by transmitting the
code (F5) from the Jig RCU again. (When the EVR mode
is released, the adjusted data is memorized.)
Fig.4-3d EE composite burst level
4.3.2.4
EE R/G/B level
(1) Observe the R OUT waveform at the measuring point (D1).
(2) Set the VCR to the EVR mode by transmitting the code (F1)
from the Jig RCU.
(3) Set the EVR address to (F2) by transmitting the code (F3)
from the Jig RCU.
(4) Transmit the code (F4) from the Jig RCU to adjust so that
the R level of the R OUT waveform becomes the specified
value (G).
(5) Release the EVR mode of the VCR by transmitting the
code (F5) from the Jig RCU again. (When the EVR mode
is released, the adjusted data is memorized.)
(6) Observe the G OUT waveform at the measuring point (D2).
(7) Repeat steps (2) to (5) above.
(8) Observe the B OUT waveform at the measuring point (D3).
(9) Repeat steps (2) to (5) above.
Fig.4-3e EE R/G/B level
4.3.2.5
EE COMPONENT PB/CB level
Signal
(A1)
(A2)
• Ext. input
• Color (colour) bar signal
Mode
(B)
• EE
Equipment
(C) • Oscilloscope
Measuring point (D) • L-1 connector pin19
EVR mode
EVR address
(F1)
(F2)
(F3)
(F4)
(F5)
• Jig code “95”
• "ADJUST02 : **"
• Jig code “22”
• Jig code “18” or “19” (C/-)
• Jig code “3C”
Specified value (G) • 1.00 ± 0.02 Vp-p (terminated)
Adjustment tool (H) • Jig RCU [PTU94023B]
Signal
(A)
• Internal colour bar
Mode
(B)
• EE
Equipment
(C) • Oscilloscope
Measuring point (D) • L-1 connector pin19
EVR mode
EVR address
(F1)
(F2)
(F3)
(F4)
(F5)
• Jig code “95”
• "ADJUST00 : **"
• Jig code “20”
• Jig code “18” or “19” (C/-)
• Jig code “3C”
Specified value (G) • 0.30 ± 0.01 Vp-p (terminated)
Adjustment tool (H) • Jig RCU [PTU94023B]
Specified
value (G)
H. rate
Signal
(A)
• Internal colour bar
Mode
(B)
• EE
Equipment
(C) • Oscilloscope
Measuring point (D1)
(D2)
(D3)
• L-1 connector pin15(R)
• L-1 connector pin11(G)
• L-1 connector pin7(B)
EVR mode
EVR address
(F1)
(F2)
(F3)
(F4)
(F5)
• Jig code “95”
• "ADJUST05 : **"
• Jig code “25”
• Jig code “18” or “19” (C/-)
• Jig code “3C”
Specified value (G) • 0.70 ± 0.02 Vp-p (terminated)
Adjustment tool (H) • Jig RCU [PTU94023B]
Signal
(A)
• Internal colour bar
Mode
(B)
• EE
Equipment
(C) • Oscilloscope
Measuring point (D) • COMPONENT PB/CB terminal
EVR mode
EVR address
(F1)
(F2)
(F3)
(F4)
(F5)
• Jig code “95”
• "ADJUST06 : **"
• Jig code “26”
• Jig code “18” or “19” (C/-)
•
Jig code “3C”
Specified value (G) • 0.70 ± 0.02 Vp-p (terminated)
Adjustment tool (H) • Jig RCU [PTU94023B]
Specified
value (G)