1-24 (No.PA019)
(10) Click [DisConnect] in the SPA menu to disconnect the system.
(11) Open the sheet [CHROMATICY MEASUREMENT(RGB)] in the Gamma adjustment file.
(12) Similarly, click [CONNECT]. Refer to Fig.4.
(13) When the connection is competed, click [MEASURE]. Refer to Fig.4.
(14) When the measurement is completed, click [DISCONNECT] to disconnect the system. Refer to Fig.4.
(15) Confirm if the three graphs shown on the [CHROMATICY MEASUREMENT(RGB)] sheet are linear. If not, the result is
determined to be FAILED.
Fig.4
(16) Open the y calculation sheet in the GAMMA adjustment file (GAMMAOFF_1.0_with color compensation).
(17) Click [CREATE gcd FILE] near the BK16 cell in the sheet and save it with an appropriate file name.
(18) Perform the procedures in step 5), 6), 7) and 8). Please note the file to be loaded is the one that is saved in step 17).
(19) Select the [R] button in the [Gamma correction] screen. Refer to Fig.4.
(20) Right-click on the Gamma curve in the Gamma correction screen to select [Copy Gamma Data].
Refer to Fig.4.
Fig.4
(21) Select [Gamma2.2] in the [Gamma correction] screen. Refer to Fig.5.
(22) Right-click on the Gamma curve in the [Gamma correction] screen to select .[Paste Gamma Data]. Confirm that the Gamma
curve for [R] is pasted. Refer to Fig.5.
Fig.5
(23) Perform the procedures in step (19), (20), (21) and (22) for [G] and [B], as well.
(24) When step (23) is completed, click [RGB Transmit All]. Refer to Fig.5.
(12)Click
(13)Click
(14)Click here
Confirm
(19)Select
(20)Select
(21)Select
(24)Click
(22)Select