E-36
RECORDING
–
Setting time codes
–
This unit has a built-in time code reader/ generator. It records time codes during recording. It
does not record the user’s bit.
Time codes are recorded according to the recording condition as follows:
Time codes are recorded in the REC RUN mode. (REC RUN: time codes run only during
recording.)
Time code recording
Time codes are preset via the TIME CODE menu. It can be
set via either the remote controller or the Main unit.
Press the OPERATE button on the Main unit or the
remote controller to turn on the power and set the
unit to the STOP mode.
* To set it with the main unit, first remove the cassette from the
unit if it is loaded.
Condition
Time code recording
Time code is preset with this unit.
Time code is not preset.
Preset time codes.
SET
MENIU
EJECT
REC
PLAY
PAUSE
REW
STOP
FF
DVCAM NTSC
PAL REC INH.
CH-1/3
CH-2/4
BR-DV3000
B
SEL.
E
Y/C
PLAY button
EJECT button
PAUSE button
FF button
STOP button
REW button
DISPLAY
BARS
MENU
SEARCH–
SET
BLANK
STILL
MODE
AUDIO
MUTING
OUT SEL.
OUT LEV.
MENU
button
button
button
button
button
SET button
• Time codes preset in the built-in time code generator are re-
corded. (First time only)
• When recording ends, the set time codes becomes void and
regeneration occurs.
Memo
The framing mode is selected from the NDF/DF item of the TIME
CODE menu. (NTSC only)
• It reads the time codes recorded on the tape and continues
recording time codes from these values. (Regeneration)
• If no time code is recorded, it starts from “00”.
* Sometimes, the time codes recorded at the beginning of the
tape may not be read.
Memo
When the REC button is held
down in the STOP mode, the
value of the built-in time code
generator is displayed.
BR-DV3000_E_p03-49
06.8.24, 1:38 PM
36