No. 51914
AV-48WP30
7
INSTALLATION
1. INSTALLATION SITE
1. The rear of this set is provided with ventilation openings. Install the set
more than 5 cm from a wall and in a location with good ventilation.
2. Avoid the following types of locations.
(1) Unstable locations (location must be able to withstand heavy weight).
(2) Locations subjected to direct sunlight.
(3) Near stoves or other heating devices.
(4) Locations subjected to humidity or oily smoke.
(5) Dusty locations.
(6) Locations with strong vibration.
2. INSTALLATION ADJUSTMENT
When installing, moving or changing the orientation of the set, perform
static convergence adjustment according to the following procedure.
1. Press the MENU key of the remote control unit.
2. Select the "CONVERGENCE" in the INITIAL SETUP menu with Function
▲
/
▼
key.
3. Press the Function / key, the convergence adjustment screen appears
with crosses (+) displayed in 9 locations.
Locations where the crosses appear in 3 colours
:
Convergence adjustment is required. Perform steps 4 to 5.
Locations where the crosses are white:
The convergence is adjusted correctly.
"
lf all the crosses are white, no convergence adjustment is needed.
4. The locations of the crosses correspond to the positions of the number keys on
the remote control. A box appears around the selected cross.
5. Press the SELECT button to change the color of the box to the color of the
cross you want to adjust (red or blue).
"
You cannot adjust the green cross.
6. Use the / and / buttons to adjust the position of the cross.
"
To cancel the adjustments before completing the procedure, press the EXIT
button.
7. Press the ENTER button to end the convergence adjustment procedure.
"
lf you do not use the TV controls for roughly one minute, the convergence
adjustment screen automatically disappears.
Fig.1
Fig.2
Wall
(more than 5cm)
VENTILATION OPENING
Summary of Contents for AV-48WP30
Page 1: ......