4.8.5 VSM PRESET SETTING
VSM PRESET TABALE
Item
Measuring
instrument
Test point
Adjustment part
Description
VSM PRESET
Remote
control unit
[5. VSM PRESET]
1. CONT
2. BRIGHT
3. SHARP
4. COLOUR
5. HUE
1. DRIVE R
2. DRIVE G
3. DRIVE B
(1) Select
5. VSM PRESET
from the SERVICE MODE.
(2) Set the PICTURE MODE to BRIGHT.
(3) Select
< 1.CONT >
.
(4) Set the initial setting value of PICTURE MODE, as
shown in the below table.
(5) Press the
[OK]
key to memorize the set value.
(6) Select
< 2.BRIGHT >
to
< 5.HUE >
in turn, and set
the values.
(7) Respectively select the "SOFT" and "STANDARD".
Make similar adjustment as same step as above.
(8) Press the
[OK]
key to set the COLOUR TEMP to
COOL.
(9) Select
< 1.DRIVE R >
.
(10) Set the initial setting value of COLOUR TEMP., as
shown in the below table.
(11) Press the
[OK]
key to memorize the set value.
(12) Select
< 2.DRIVE G >
and
< 3.DRIVE B>
in turn,
and set values.
(13) Respectively select the "WARM" and "NORMAL".
Make similar adjustment as same step as above.
Item
Variable
range
Setting value
PICTURE MODE
COLOUR TEMP.
BRIGHT
STANDARD
SOFT
COOL
NORMAL
WARM
1.CONTRAST
-16~+16
+16
+5
-3
---
---
---
2.BRIGHT
-16~+16
0
0
0
---
---
---
3.SHARP
-16~+16
0
0
0
---
---
---
4.COLOUR
-16~+16
0
0
0
---
---
---
5.HUE
-16~+16
0
0
0
---
---
---
1.DRIVE R
-64~+63
---
---
---
-5
0
+6
2.DRIVE G
-64~+63
---
---
---
-5
0
0
3.DRIVE B
-64~+63
---
---
---
0
0
0