(No.YA366)1-23
BOW
Signal
generator
Remote
control unit
[4. DEF]
12. BOW
(1) Receive the PAL cross hatch signal.
(2) Set the ZOOM mode to REGULAR.
(3) Select 4. DEF from the SERVICE MODE.
(4) Select
< 12.BOW >
.
(5) Adjust to bring the vertical lines straight.
(6) Press the
[OK]
key to memorize the set values.
V. S-SHAPE
CORRECTION &
LINEARITY
Signal
generator
Remote
control unit
[4. DEF]
13. V-S. CR
14. V-LIN
• When the vertical linearity has been deteriorated
remarkably, perform the following steps.
(1) Receive the PAL cross hatch signal.
(2) Set the ZOOM mode to REGULAR.
(3) Select 4. DEF from the SERVICE MODE.
(4) Select
< 14. V-LIN >
.
(5) Set the initial setting value of
< 14. V-LIN >
.
(6) Select
< 13. V-S.CR >
.
(7) Set the initial setting value of
< 13. V-S.CR >
.
(8) Adjust
< 14. V-LIN >
and
< 13. V-S.CR >
so that the
spaces of each line on TOP, CENTRE and
BOTTOM become uniform.
(9) Press the
[OK]
key to memorize the set values.
Item
Measuring
instrument
Test point
Adjustment part
Description
Bring the vertical lines straight.
TOP
CENTRE
BOTTOM
Summary of Contents for AV-29L6SU, AV-29L6BU