1-22 (No.YA366)
TRAPEZIUM
Signal
generator
Remote
control unit
[4. DEF]
5.TRAPEZ
(1) Receive the PAL cross hatch signal.
(2) Set the ZOOM mode to REGULAR.
(3) Select 4. DEF from the SERVICE MODE.
(4) Select
< 5.TRAPEZ >
.
(5) Set the initial setting value of
< 5.TRAPEZ >
.
(6) Adjust to bring the vertical lines at the right and left
edges of the screen in parallel.
(7) Press the
[OK]
key to memorize the set values.
UPPER/LOWER
CORNER PIN
Signal
generator
Remote
control unit
[4. DEF]
7.COR-UP
8.COR-LO
9.COR-UP-S
10.COR-LO-S
(1) Receive the PAL cross hatch signal.
(2) Set the ZOOM mode to REGULAR.
(3) Select 4. DEF from the SERVICE MODE.
(4) Select
< 8. COR-LO >
.
(5) Set the initial setting value of
< 8. COR-LO >
.
(6) Adjust to bring the straight line at the lower corner.
(7) Select
< 7. COR-UP >
.
(8) Set the initial setting value of
< 7. COR-UP >
.
(9) Adjust to bring the straight line at the upper corner.
(10) Adjust
< 8. COR-LO >
and
< 7. COR-UP >
so that
the vertical lines at the four corners on the screen
are straight.
(11) If the extreme upper & lower corners are little pin or
barrel, chose
< 9. COR-UP-S >
,
< 10. COR-LO-S >
and adjust to get straight.
(12) Press the
[OK]
key to memorize the set values.
PARALLELOGRAM
(TILT)
Signal
generator
Remote
control unit
[4. DEF]
11.ANGLE
(1) Receive the PAL cross hatch signal.
(2) Set the ZOOM mode to REGULAR.
(3) Select 4. DEF from the SERVICE MODE.
(4) Select
< 11. ANGLE >
.
(5) Adjust to bring the vertical lines straight.
(6) Press the
[OK]
key to memorize the set values.
Item
Measuring
instrument
Test point
Adjustment part
Description
Parallel
Straight
Straight
Bring the vertical lines straight.