Tr
oubleshooting Ener
giser P
roblems
Page 30
© JVA Technologies. www.jva-fence.com
Error
Code #
Red LED
Flashes
LCD Display
Meaning
8
8
“Er 08”
Self-calibration failure - insuffi-
cient output
9
9
“Er 09”
Self-calibration failure – insuffi-
cient capacitor charge
10
10
“Er 10”
Capacitor failure, charged too
quickly
11
11
“Er 11”
Calibration error, voltage reading
too low for fence conditions
21
N/A
“Er 21”
Opto-coupler failure
For errors 3 and 5 the energiser will try and recover these three errors
which are classed as severe errors. This automatic recover process will oc-
cur at 7 minute intervals. Error 4 is classed as a fatal error. The energiser
will not attempt to automatically restart due to safety concerns. Errors 2
and 6 indicate the battery voltage is either too low or too high. The ener-
giser will restart as soon as the voltage returns to the correct range. All
other errors indicate an internal malfunction.
Should the error continue to re-occur, please return the unit to a qualified
service centre for repair. There are no user serviceable parts inside the
energiser. All internal fuses will automatically reset themselves.