JV
A M
odels and F
ea
tur
es
Page 16
© JVA Technologies. www.jva-fence.com
4.2 POWER BUTTON
•
If the energiser is off, push the power button to turn it on.
•
If the beeper is giving an audible warning, push the power button to
silence the beeper for 10 minutes.
•
If the energiser is on, push the power button to turn it off.
4.3 ENERGISER LED AND LCD DISPLAY
Status
red LED:
•
Flashes slowly (once per pulse) when there is a heavy fence load. This
means the fence may have a fault. This will not harm the energiser, but
your electric fence may not be effective. See Troubleshooting Ener-
giser Problems below.
•
Two Flashes shows the battery is low. You should change or recharge
the battery. See Troubleshooting Energiser Problems below.
•
More than two flashes shows an error code (this is rare). Some errors
can cause the energiser to shut down. See Troubleshooting Energiser
Problems below.
Energiser OK
green LED:
•
Flashes with each pulse to show the unit is on and operating correctly.
LCD Screen
- The LCD shows:
•
Operating Status information
•
Battery voltage and capacity
•
Output Voltage (Kilo volts)
•
Stored Energy (Joules)
•
Error codes (See section 6.5)