background image

GER 

|  JUST Normlicht GmbH  |  Ve Produktion  |  Tobelwasenweg 24  |  73235 Weilheim / Teck  |  Tel.: +49 (0) 7023 9504-0  |  Fax: +49 (0) 7023 9504-52 

US

 

|  JUST Normlicht Inc.  |  2000 Cabot Blvd. West, Suite 120  |  Langhorne, PA 19047-2408  |  Phone: +1 267 852 2200  |  Fax: +1 267 852 2207  

FR

 

|  JUST Normlicht France SARL  |  3 Rue Louis Pasteur  |  67240 Bischwiller  |  Tel.: +33 (0)3880628-22  |  Fax: +33 (0)3880628-23

Assembly and instruction manual 

DLS Color Viewing Light v8 S 

DLS Color Viewing Light v8 Hybrid S

Art. Nr.: 203278 / *203279

Art. Nr.: 203080 / *203079

DLS COLOR VIEWING LIGHT V8 S

Summary of Contents for 203079

Page 1: ...Blvd West Suite 120 Langhorne PA 19047 2408 Phone 1 267 852 2200 Fax 1 267 852 2207 FR JUST Normlicht France SARL 3 Rue Louis Pasteur 67240 Bischwiller Tel 33 0 3880628 22 Fax 33 0 3880628 23 Assembly and instruction manual DLS Color Viewing Light v8 S DLS Color Viewing Light v8 Hybrid S Art Nr 203278 203279 Art Nr 203080 203079 DLS COLOR VIEWING LIGHT V8 S ...

Page 2: ...troduction 3 Intended use 4 Safety precautions 5 Product description 8 Packing list and accessorries 9 Mounting 10 Operating instructions 11 Technical and electrical specifications 13 Troubleshooting 14 Maintenance information 15 Warranty policy 16 Return Material Autorisation RMA 17 Contact details 19 Document history 20 ...

Page 3: ...xplain the device you have purchased and its features This will ensure your safety as well as reliable operation and a long service life The technical data illustrations and dimensions in this manual may vary due to future product enhancement Please check online for the most current product documentation Keep these instructions on hand for future reference If you have any questions or suggestions ...

Page 4: ...nd fluorescent materials and surfaces according to valid norms and standards The DLS Color Viewing Light v8 booths may only be operated in an indoor environment protected from rain humidity dust and condensation Never use DLS Color Viewing Light v8 products in poorly ventilated locations where there is a risk of explosion from gas or dust Please note that JUST Normlicht light sources are not inten...

Page 5: ...l part of our quality control process and is not due to prior use or a returned product This does not affect the product use or function and does not constitute a reason for return Keep these operating instructions for later use or inquiries If you pass the lamp on to a third party please include the operating instructions These operating instructions can be requested from the dealer as a PDF file...

Page 6: ...any repairs or modifications to your proofing device or the power cable Defective luminaires may only be replaced by the manufacturer because incorrect repairs can cause considerable consequential damage In case of defects contact the responsible sales department see page 18 Do not replace any parts of the device unless this is expressly provided for in the operating instructions Care instructions...

Page 7: ...ing company of electrical and electronic equipment Caution UVA Radiation Do not look directly into the souce Avoid shining the light on uncovered skin less than 1 meter away for long periods of time Other notes Protect your device from moisture when in use Do not use multiple sockets or extension cords Avoid pulling on the power supply to disconnect the device from the power supply Only use access...

Page 8: ...haracteristics shadow and glare free CAD based prismatic diffuser expected life of 50 000 hours maintenance free no tube replacement necessary 5 illuminants according to CIE standard illuminants for colorimetry D50 e g ISO 3664 2009 switch off on UV content D65 e g ISO 3668 2014 switch off on UV content UV A ALT1 according CIE 15 2018 LED B1 B5 2733 6598 K Ra 80 ALT2 according CIE 15 2018 LED B1 B...

Page 9: ... Accessories Only use the accessories for your viewing booth that are supplied with the device or provided by the manufacturer Use of inadequate equipment can create significant hazards For example prevent tipping with suitable wall mounts bases or cabinets and damage to the coated viewing surface with unsuitable sample holders or rigid stands Do not attach any objects to the product that are not ...

Page 10: ...M4 screws Step 2 Mount the sidewalls to the base using the 4 x provided M4 screws Step 4 Mount the DLS lamp on the assembled base using the 4 x provided M4 screws Step 3 Turn the DLS lamp upside down Remove the 4 x M4 lens head screws from the glass panel Position the protective screen as shown in the picture under the glass panel and reinstall with the loosened 4 x M4 screws ...

Page 11: ...the light The display F lights up 2 Choose illuminant A or B With the keys you can dimm the illuminant 3 You can switch off the UV content by using the UV key E 4 Press the UV key E for two seconds to activate the UV only function 5 Turn off the luminaire by using the back main swich when you finished the color assessment Notes The ALT 1 C and ALT 2 D keys are programmed by the manufacturer accord...

Page 12: ...nd OK key 4 Select the first type of light you want to by pressing the respective key A D 5 Confirm with OK 6 Set the desired light intensity with the keys only possible for A and B 7 Save with OK 8 Confirm S 1 5 with the key S sequence 1 means that you select the first light type 9 S 2 5 displayed 10 Select the second illuminant A D you want 11 Select the illuminant again to open it 12 Repeat ste...

Page 13: ...wing booth Hybrid Viewing booth Illuminant types CIE D50 5000 K CIE D65 6500 K UV ONLY UV A CIE B1 B5 2733 6598 K Ra 80 CIE D50 5000 K CIE D65 6500 K UV ONLY UV A CIE B1 B5 2733 6598 K Ra 80 TL84 Ra Color Rendering Index ø 95 95 Metamerism Index visible range 0 8 0 8 Metamerism Index UV range 0 6 0 6 Chromaticity error 0 002 0 002 Chromaticity coordinate 10 D50 x 0 3478 y 0 3595 D65 x 0 3138 y 0 3...

Page 14: ...k main switch at the back of the housing and switch them on if necessary The light does not turn on There is no power or the fuse for the light has blown First check whether you ve got power and whether the device is connected to the right power supply in accordance with its specifications 110 V or 230 V Check the lamp s fuse or have it checked by an electrician You can usually find it at the devi...

Page 15: ...ecessary The manufacturer recommends that the booth be maintained in case of possible deviating color temperatures D50 D65 after 50 000 operating hours to ensure uniformity and consistent light quality If fluorescent tubes are installed for ALT1 or ALT2 these must be replaced after 2 500 operating hours due to the aging process For maintenance please contact your local dealer see page 18 ...

Page 16: ...s not manufactured distributed or approved by JUST Normlicht 5 Any attachments or modifications to the warranted goods that are not manufactured distributed or approved by JUST Normlicht 6 Failure to use electrical protection Consumable parts and product cleaning are also not covered by the warranty Warranty is extended to the purchasing party only and not transferable to a second party if re sold...

Page 17: ...duct purchaser shall obtain a Return Material Authorization RMA number from JUST Customer Service Department and mark the outside of all packages with the RMA number Products must be new unused and contain all the original packaging instruction manuals and accessories There is no restocking charge due to errors by JUST if correct order information was furnished with the order Custom order returns ...

Page 18: ...ier are responsible for any shipping damages Shipping damages resulting from improper packaging will be at the customer s responsibility After repair JUST will return the product ground freight prepaid for in warranty items For any other shipment method customer must pay the difference in freight Non Warranty items will be invoiced for any parts labor and shipping charges Products will not be acce...

Page 19: ...ermany International phone 49 7023 9504 0 E Mail info just normlicht com Sales Team USA Canada Mexico phone 1 267 852 2203 E Mail sales just normlicht com Sales Team France Benelux Spain Portugal Morocco Algeria Libya Tunisia phone 33 3 8806 2822 E Mail info just normlicht fr For more infortamion about our company and products visit our website www just normlicht com our social media channels ...

Page 20: ... 20 Errors and changes are reserved Assembly and instruction manual DLS Color Viewing Light v8 S Rev 1 0 Document History Rev Nr Modification date Modification Internal ID ...

Page 21: ......

Reviews: