12
Errors and changes are reserved.
Assembly and instruction manual
|
DLS Color Viewing Light v7 XL
|
Rev 1.0
Technical and electrical specifications
Electric data
Maximum electric power
45 W
Electrical operating power
40 W
Operating voltage
230 V / 110V*
Tension frequency
50 / 60 Hz
Connection cable
power cable, angle plug type 303 to IEC so-
cket type 601 / NEMA 5-15P Male*
Maximum continuous current (continuous
operation)
0,2 A / 0,4 A*
Operating mode
S1: Continuous operation
Expected lifetime (continuous operation)
>50.000 h
Photometric data and colormetric characteristics
Illuminant types
CIE D50 (5000 K) , CIE D65 (6500 K),
UV-ONLY (UV-A)
Ra (Color Rendering Index) ø
>95
Metamerism Index (visible range)
≤ 0,8
Metamerism Index (UV-range)
≤ 0,6
Chromaticity error
<0,002
Chromaticity coordinate (10°)
D50: x = 0,3478 y =0,3595, D65: x = 0,3138
y = 0,3309
Dominant wavelength UV-ONLY
365 nm
Radiant power UV-ONLY
6 W
Risk assessment according to DIN-EN-62471
D65+UV / D50+UV: RG0
UV-ONLY: RG1
Mechanical data
Housing
Aluminium
Lens
special prismatic lens , UV-transmissive
Protection class
IP 52
Permitted ambient temperature
0°C -40°C / 32°F -104°F
*Data for US version of the product