Elektroapparate AG
Technical information
Technical Support
Language
EN
IMPRESSA XJ9 One Touch TFT
Professional
Author: Patrik Studer
Checked:
Approved:
Docu.-name:
Technische_Informationen_XJ9_EN.doc
L:\Geräte\Linie_XJ\XJ9\Schulungsunterlagen\E\Technische_
Informationen_XJ9_EN.doc
Date:
Rev. A:
Rev. B:
Rev. C:
Rev. D:
Rev. E:
Rev. F:
26.06.2012
15.11.2012
23.11.2012
12.03.2013
02.04.2013
08.08.2013
Page 16/17
20
Error messages:
If there is a malfunction, an error message as described below is shown on the display:
The appliance switches-OFF automatically 5 sec. after an ERROR
Display
Designation
ERROR 1
COFFEE: Temperature sensor notify “value below tolerance”
ERROR 2
COFFEE: Temperature sensor notify “value above tolerance”
ERROR 5
Heating up not possible
ERROR 6
“Positioning” / “Initialisation” of multi-valve not possible
ERROR 8
“Positioning” / “Initialisation” of brewing unit not possible
ERROR 9
Logic relay is defective
ERROR 10
Heating was too hot (mains interferences received)
Cleaning/decalcification cannot be carried out, as there had been used a
steam-product before
Intelligent fresh water kit
Check Kit 1
Security switch inactive
Check Kit 2
Timeout water flow
Check Kit 3
Sensor notify “value below tolerance”
Check Kit 4
Water level 1 failure but water level 2 OK
Check Kit 6
Water level 1 and 2 OK
Check Kit 7
No communication to Mini-Hub