J301A-001 Audio Controller
Installation and Operating Manual
Rev A
Page 14
2.5.3.12
VOX
2.5.2.13
Connector Maps
This section contains connector maps and interconnects that are automatically generated to show changes that
affect the installation of the J301A-001, such as switch labels and voltages. See
2.5.4
Other Configuration Features
In the J301A-001 Product Information Window, the model number, serial number and check sum of the J301A-001
audio panel can be viewed.
2.6
Installation Kit
The kit required to install this unit is not included with the unit.
The installation kit (Part # INST-J301A) consists of the following:
Quantity
Description
JAC Part #
1
25 Socket Positions, Zinc Plated, D-Sub - Crimp Socket Housing
CON-3460-0125
1
50 Socket Positions, Zinc Plated, D-Sub - Crimp Socket Housing
CON-3460-0150
1
15 Pin Clamshell, Hardware - Plastic D-Sub Hoods
CON-5300-0115
1
25 Pin Clamshell, Hardware - Plastic D-Sub Hoods
CON-5300-0125
1
50 Pin Clamshell, Hardware - Plastic D-Sub Hoods
CON-5300-0150
90
Machined 20 - 24 AWG, MIL spec, D-Sub - Crimp Socket
CON-3320-2024M
3
D-Sub 4-40, Hardware - Jack Screws
CON-5150-0440
2
0.375" Inside Diameter, Hardware - Tag Ring
CON-5500-0375
1
0.625" Inside Diameter, Hardware - Tag Ring
CON-5500-0625
1
1" Inside Diameter, Heat Shrink Tube
WIR-HTSK-1000
2
3/4" Inside Diameter - Black, Heat Shrink Tube
WIR-HTSK-0750
2.6.1
Recommended Crimp Tools
Standard D-Sub Crimp Tool Chart
Tool Type
Hand crimping tool
Positioner
Insertion/extractor tool
POSITRONIC
9507-0-0-0
9502-5-0-0
4711-2-0-0
DANIELS
AFM 8
K13-1
91067-2
MIL-SPEC
M22520/2-01
M22520/2-08
M81969/1-02
2.7
Installation Drawings
The drawings and documents required for Installation can be found in
2.7.1
Generation of Custom Drawings
The interconnects and connector maps in Appendix A of this manual are generic drawings based on the standard
version of the J301A-001. However, if a unit has been configured using JAC’s ProCS™ software to change switch
legends or lighting voltages, the software can be used to generate fully customized interconnects and connector
maps for use by the installer.
The VOX OFF Delay Time can be adjusted
from 0.50 to 2.00 sec (
Default 1 sec
).