4 - INSTALLATION

For ease of installation, use the following guide:

4.1 - Mounting the support bracket.
4.2 - Mounting the hood unit.
4.3 - Electrical connection and functional check.
4.4 - Exhaust and filter connection.
4.5 - Mounting the telescopic chimney stack.

4.1 - Mounting the support bracket. Backing.

Refer to (figs. 2a-b):

1 -

On the wall draw a vertical line to the ceiling, in the centre of the area where the hood is to be
mounted. This enables vertical alignment of the various parts.

2 -

Position the bracket 

I

a) Place the bracket 

I

 on the wall, aligning its centre (notches) on the vertical line at a distance

between the axis of its holes and the cooking surface:
1 - with backing: d = 300 + 

H

 mm, where 

H

 = height in mm of the visible part of the

backing. Due to the various types of backings available, this measurement must be taken
directly on the backing provided.
2 - without backing: d = at least 950 mm.

N.B. - Check that the bracket I is in a horizontal position. Minor adjustments can be made
using the hood regulating screws (see below).

b) Mark the centres of the two eyelet holes of the bracket on the wall.

3 - Using an 8 Ø mm bit, drill the marked centres, then fix firmly the bracket 

I

 using the 8 Ø

mm rawl plugs and screws provided.

4 - Backing (optional)

In this manner the distance of the cooker hood from the cooking surface is determined by the
height of the backing 

B

 and by the height of the bases. The backing is to be mounted before

mounting the hood unit and, if you wish to fix both upper and lower parts to the wall, it must
be mounted at the exact height before mounting the bases or the relative upper surface. Since
this operation is complex, it must be performed only by the kitchen installer or by competent
persons who know all the final measurements of the kitchen units. For upper fixing only,
proceed as follows:
a) Place the backing on the base surface as in fig. 2a. Set it against the wall and centre it with
respect to the base.
b) On the wall, mark the centres of the two holes of the upper flaps.
c) Using an 8 Ø mm bit, drill the holes in the wall and fix the backing using the 8 Ø mm rawl
plugs and screws provided.
d) If it is necessary to block the lower part, this must be done by the installer.

4.2 - Mounting the hood unit (fig. 3)

1 - Turn the two screws 

V

 (placed where the hood will be hooked) about halfway in.

2 - Hook the back part of the hood to the support bracket 

I

 fixed to the wall.

3 - Turn the screws 

V

 for vertical adjustment of the hood and level it horizontally.

4 - Insert and tighten the central fixing screw 

V1

 (supplied) for final blocking.

Part 1 - INSTALLATION INSTRUCTIONS

Summary of Contents for JDK7090G

Page 1: ...Mega Libretto Istruzioni Instructions Booklet Mode d emploi Bedienungsanleitung Gebruiksaanwijzing ...

Page 2: ...ond 14 Montage des Haltebügels Rückwand 21 Montage van de draagbeugel Spatscherm 27 Montaggio del corpo cappa 5 Mounting the hood unit 10 Montage du corps de la hotte 15 Montage des Haubenkörpers 22 Montage van het kaplichaam 27 Connessione elettrica e controllo funzionale 6 Electrical connection and functional check 11 Connexion électrique et contrôle fonctionnel 16 Elektrischer Anschluß und Funk...

Page 3: ...18 Areitsweise der Dunsthaube 24 Gebruik 29 Manutenzione 7 Maintenance 12 Entretien 18 Wartung und Pflege 24 Onderhoud 29 Filtri antigrasso metallico 7 Metal grease filters 12 Filtres anti graisse métalliques 18 Metall Fettfilter 24 Metalen vetfilter 29 Filtri al carbone attivo 7 Active carbon filter 12 Filtre à charbon actif 19 Aktiv Kohlefilter 25 Koolstoffilters 30 Illuminazione 8 Illumination ...

Page 4: ...od ducting must not be connected to a central heating flue radiator or a water heater 3 2 Before connection to the mains supply ensure that the mains voltage corresponds withthe voltage on the rating plate inside the hood 3 3 Connect the hood to the mains supply via a double pole switch which has 3 mm clearance between the contacts When using a plug to connect the hood to the power supply ensure t...

Page 5: ...l plugs and screws provided 4 Backing optional In this manner the distance of the cooker hood from the cooking surface is determined by the height of the backing B and by the height of the bases The backing is to be mounted before mounting the hood unit and if you wish to fix both upper and lower parts to the wall it must be mounted at the exact height before mounting the bases or the relative upp...

Page 6: ...s as follows a The chimney stack fitting R must be separated from the inside ring F by cutting the four joining tabs fig 6 Part D may be used if an intermediary shelf is installed c Position ring F on the ceiling or upper shelf in line with the hood outlet fig 7 and fix it with two screws if on the shelf or two screws and two rawl plugs provided if to the ceiling d Insert the upper chimney stack i...

Page 7: ...ontinuous flow of air when the level of cooking fumes is low BUTTON V2 Medium speed suitable for most normal operating conditions This gives an excellent ratio between treated air flow and noise level BUTTON V3 High speed suitable to deal with heavy cooking fumes even for long periods of time 3 MAINTENANCE Continued maintenance guarantees proper functioning and best performance throughout time Spe...

Page 8: ... will stay hooked to tabs Z b Slide the glass to one side until the opposite end is free arrow 1 then pull gently down arrow 2 then slide in the opposite direction arrow 3 until the glass is freed Replace the bulb or neon tube and replace the glass reversing the removal sequence 3 5 Cleaning For normal hood cleaning Do not use wet cloths or sponges or jets of water Do not use solvents or alcohol w...

Page 9: ...31 1 2 ...

Page 10: ...32 3 4 5 6 ...

Page 11: ...33 7 8 9 10 11 12 ...

Page 12: ...34 V3 V2 V1 L 13 14 15 16 17 ...

Page 13: ...35 ...

Page 14: ...u marquage CE Dieses Gerät entspricht den europäischen Niederspannungsrichtlinien 73 23 EWG zur elektrischen Sicherheit den europäischen Richtlinien 89 336 EWG zur elektromagnetischen Verträglichkeit und den Richtlinien 93 68 EWG zur CE Kennzeichnung Dit apparaat voldoet aan de Europese Laagspanningsrichtlijn 72 23 EEG inzake de elektrische veiligheid en aan de Europese normen 89 336 EEG inzake de...

Reviews: