20. Press the power switch to the on (|) position.
RELATED DOCUMENTATION
QFX10000 AC Power System
QFX10000 DC Power System
Maintaining QFX10000 Switch Interface Boards
IN THIS SECTION
Removing a QFX10000 Switch Interface Board | 315
Installing a QFX10000 Switch Interface Board | 320
Removing a QFX10000 Switch Interface Board
A QFX10008 and QFX10016 switch has six Switch Interface Boards (SIBs) that are located in the middle
of the chassis behind the fan trays. SIB 0 through SIB 2 are located behind the left fan tray and SIB 3
through SIB 5 are located behind the right fan tray. You must remove the appropriate fan tray to access
the failing SIB. See
Removing a QFX10008 Fan Tray
.
Ensure you have the following equipment on hand before replacing a SIB:
• Electrostatic bag or antistatic mat
• Electrostatic discharge (ESD) grounding strap
To remove a SIB (see
):
1. Take the SIB offline using the
request chassis sib slot
slot number offline
command.
NOTE: If you suspect the SIB is faulty and want to ensure packets do not flow through the
SIB, power down the SIB instead of taking the SIB offline. To power down the SIB, use the
set
315
Summary of Contents for QFX10016
Page 1: ...QFX10016 Switch Hardware Guide Published 2022 09 09...
Page 10: ...Compliance Statements for Environmental Requirements 428 x...
Page 15: ...Figure 1 on page 5 shows a front and rear view of the QFX10016 4...
Page 16: ...Figure 1 QFX10016 Front and Rear 5...
Page 239: ...RELATED DOCUMENTATION QFX10008 Installation Overview QFX10002 System Overview 228...
Page 270: ...1 ESD point Figure 113 ESD Point on QFX10016 Chassis Rear 1 ESD point 259...
Page 287: ...Figure 130 Installing a JNP10K PWR AC2 in a QFX10016 276...
Page 322: ...Figure 159 Installing a JNP10K PWR DC2 in QFX10016 311...
Page 366: ...5 CHAPTER Troubleshooting Troubleshooting QFX10000 Modular Chassis 356...