RJ-45 to DB-9 serial port adapter (provided)

Management host, such as a PC, with an Ethernet port (not provided)

Install the Large Mounting Shelf in an Open-Frame Rack

Before front-mounting the router in an open-frame rack, install the large mounting shelf on the rack. The following table

specifies the holes in which you insert screws to install the mounting hardware in an open-frame rack (an X indicates a

mounting hole location). The hole distances are relative to one of the standard U divisions on the rack. For reference, the

bottom of all mounting shelves is at 0.04 in. (0.02 U) above a U division.

Large Shelf

Distance Above U Divisions

Holes

X

17.26 in. (43.8 cm) 9.86 U

30

X

15.51 in. (39.4 cm) 8.86 U

27

X

13.76 in. (34.9 cm) 7.86 U

24

X

12.01 in. (30.5 cm) 6.86 U

21

X

10.26 in. (26.0 cm) 5.86 U

18

X

8.51 in. (21.6 cm) 4.86 U

15

X

6.76 in. (17.1 cm) 3.86 U

12

X

5.01 in. (12.7 cm) 2.86 U

9

X

3.26 in. (8.3 cm) 1.86 U

6

X

1.51 in. (3.8 cm) 0.86 U

3

X

0.88 in. (2.2 cm) 0.50 U

2

0.25 in. (0.6 cm) 0.14 U

1

To install the large mounting shelf:

1. On the rear of each rack-rail, install cage nuts, if needed, in the holes specified in the table.

2. Partially insert a 12-24, ½-in. screw into the highest hole specified in the table.

3. Hang the shelf over the mounting screws using the keyhole slots located near the top of the large shelf flanges.

3

Summary of Contents for EX9214

Page 1: ...Juniper Networks EX9214 Ethernet Switch you need One large mounting shelf provided Mounting screws The following mounting screws are provided Eight 12 24 in screws to mount the large mounting shelf on...

Page 2: ...st strap with cable provided 2 5 mm flat blade screwdriver not provided Power cord with a plug appropriate for your geographical location for each power supply not provided Ethernet cable with an RJ 4...

Page 3: ...lves is at 0 04 in 0 02 U above a U division Large Shelf Distance Above U Divisions Holes X 17 26 in 43 8 cm 9 86 U 30 X 15 51 in 39 4 cm 8 86 U 27 X 13 76 in 34 9 cm 7 86 U 24 X 12 01 in 30 5 cm 6 86...

Page 4: ...rack mount the heaviest unit at the bottom and mount the other units from the bottom to the top in order of decreasing weight To install the switch using a mechanical lift 1 Safely remove all componen...

Page 5: ...t mounting flanges of the switch align with the holes in the rack rails 9 Move the lift away from the rack 10 Install a 10 32 in screw into each of the open mounting holes aligned with the rack starti...

Page 6: ...recommended receptacle when using the power supply in one feed mode If you are using the power supply in two feed mode plug the second power cord into the receptacle on the power supply NOTE Each powe...

Page 7: ...switch 3 Move the input mode switch to position 0 for one feed or position 1 for two feeds NOTE For a fully redundant configuration in two feed mode eight feeds are required For a nonredundant config...

Page 8: ...wo feeds On INPUT 0 attach the negative DC source power cable lug to the 48V input terminal Repeat this step for INPUT 1 if using two feeds CAUTION Ensure that each power cable lug seats flush against...

Page 9: ...steadily The INPUT OK is lit amber if the voltage at that input is in reverse polarity Check the polarity of the power cables to fix the condition 13 Set the power switch of the DC power supply to the...

Page 10: ...crypted password or an SSH public key string DSA or RSA instead of a clear text password 4 Create a management console user account edit root set system login user name authentication plain text passw...

Page 11: ...t edit root set routing options static route remote subnet next hop destination IP retain no readvertise 11 Configure the telnet service at the edit system services hierarchy level edit root set syste...

Page 12: ...authorized service personnel Before installing the switch read the planning instructions in the EX Series documentation to ensure that the site meets power environmental and clearance requirements fo...

Page 13: ...lines remove jewelry including rings necklaces and watches Metal objects heat up when connected to power and ground and can cause serious burns or become welded to the terminals Power Cable Warning J...

Reviews: