Switching cycle counter DOWN

Display of the switching cycles in the DOWN
direction with the factor 10, e.g. the value 5 x
10 is displayed for 50 switching cycles.

Total DOWN operating hours

Display of the operating hours in the DOWN
direction since the start of operation.

Operating hours DOWN

Display of the operating hours in the DOWN
direction since the last restart in the Settings
window. 

i

The value can be updated using the arrow next to the display values.

6.3 Accessories

Power supply 12 V, for rail mounting

Art. No. NT 1220 REG VDC

Master receiver for rail mounting

Art. No. FM FK 32 REG

eNet server

Art. No. ENET-SERVER

6.4 Warranty

We reserve the right to make technical and formal changes to the product in the interest of
technical progress.
We provide a warranty as provided for by law.
Please send the unit postage-free with a description of the defect to our central customer
service office.

ALBRECHT JUNG GMBH & CO. KG

Volmestraße 1
58579 Schalksmühle

Telefon: +49.23 55.8 06-0
Telefax: +49.23 55.8 06-2 04
[email protected]
www.jung.de

Service Center

Kupferstr. 17-19
44532 Lünen
Germany

10/10

82581813
J:0082581813

12.03.2014

eNet

Radio blinds actuator for rail mounting

Summary of Contents for FM J 50700 REG

Page 1: ...nnection of several motors to an output it is essential to observe the corresponding instructions of the manufacturers and to use a cut off relay if necessary The motors may be destroyed Risk of injur...

Page 2: ...ed Slat change over time can be saved Fabric stretching for awnings Status indicator via LED Can be set with eNet server Change over time for direction change Running direction invertible Operation lo...

Page 3: ...up live parts in the working environment Fitting the device o Mount device on DIN rail Output terminals must be at the top Connect bus line Figure 2 Connection diagram of bus line Labelling Colour Con...

Page 4: ...de Figure 4 Operating mode switch Switch position Function PC Operating mode and parameter set with eNet server Ht Commission determine running time It Commission determine slat time O Blind mode of o...

Page 5: ...mode switch figure 4 is in the Venetian blind O or rolling shutter P position o Turn the operating mode switch 2 to the I t position until the blind shutter reaches the upper end position o Turn oper...

Page 6: ...itter all connections must be disconnected individually Resetting the device to the factory setting All connections to radio transmitters are disconnected and parameters are reset to default setting I...

Page 7: ...the factory setting Operating mode Roller shutter Venetian blind Awning Basic setting Roller shutter Roller shutter A rolling shutter or an awning is controlled for which the Fabric stretching functio...

Page 8: ...hannel Priority restraint 0 4 Basic setting 2 Specifies the priority for recalling and removing a scene of type Forced position for the channel Priority wind alarm 0 4 Basic setting 3 Specifies the pr...

Page 9: ...elay contact closed This parameter can be reset to 0 for example after exchanging the load The Reset button is used to reset the counter to 0 The device must be programmed to apply the change Informat...

Page 10: ...ly 12 V for rail mounting Art No NT 1220 REG VDC Master receiver for rail mounting Art No FM FK 32 REG eNet server Art No ENET SERVER 6 4 Warranty We reserve the right to make technical and formal cha...

Reviews: