background image

3 Function

System information

This device is a part of the eNet system.
High transmission reliability at a radio frequency of 868 MHz is achieved by the transmission
behaviour and bidirectional data transfer.
The range of a radio system depends on various external circumstances. The range can be
optimised by the choice of installation location.
You can find further information about the eNet system on our website.
The device may be operated in all EU and EFTA countries.

Intended use

-

Controlling electrically driven Venetian blinds, rolling shutters and awnings

-

Operation with suitable eNet radio transmitters

-

Operation with power supply RMD and receiver module RMD cover or eNet server (see
accessories)

-

Installation in distribution boxes on DIN rail according to EN 60715

Product characteristics

-

Operating mode switch for switch-over to blind actuator, shutter actuator or
parameterisation via eNet server

-

Positioning of the Venetian blind and slats via scene recall

-

Position for sun protection and twilight can be saved

-

Status feedback to radio transmitter

-

Switchable output with 

Prog

 button

-

Blind/shutter running time can be saved

-

Slat change-over time can be saved

-

Fabric-stretching for awnings

-

Status indicator via LED

Can be set with eNet server:
-

Change-over-time for direction change

-

Running direction invertible

-

Operation locks

-

Position for sun protection, twilight, lock-out protection and wind alarm

i

If settings are changed with the eNet server, operation and signalling could vary from what
is described here.

i

The parameter list is in the Internet in the documentation for this device.

Supplementary functions with eNet server:
-

Update of the device software

-

Reading of error memory

Behaviour in case of bus voltage failure and return

If the bus voltage fails, the actuator switches off. The response to bus voltage return can be
parameterised with eNet server.
Default setting: no action.

4 Operation

Operation with radio transmitters

Operation is with radio transmitters, please observe the radio transmitter instructions.

Operation with Prog button

o

Press 

Prog

 button briefly.

A moving blind/shutter is stopped and a stationary blind/shutter is briefly activated, e.g. for
slat change-over.
The control direction is changed when the button is pressed again.

o

Press the 

Prog

 button for longer than one second but shorter than four seconds.

The motor moves to the end position.

2/10

82581813
J:0082581813

12.03.2014

eNet

Radio blinds actuator for rail mounting

Summary of Contents for FM J 50700 REG

Page 1: ...nnection of several motors to an output it is essential to observe the corresponding instructions of the manufacturers and to use a cut off relay if necessary The motors may be destroyed Risk of injur...

Page 2: ...ed Slat change over time can be saved Fabric stretching for awnings Status indicator via LED Can be set with eNet server Change over time for direction change Running direction invertible Operation lo...

Page 3: ...up live parts in the working environment Fitting the device o Mount device on DIN rail Output terminals must be at the top Connect bus line Figure 2 Connection diagram of bus line Labelling Colour Con...

Page 4: ...de Figure 4 Operating mode switch Switch position Function PC Operating mode and parameter set with eNet server Ht Commission determine running time It Commission determine slat time O Blind mode of o...

Page 5: ...mode switch figure 4 is in the Venetian blind O or rolling shutter P position o Turn the operating mode switch 2 to the I t position until the blind shutter reaches the upper end position o Turn oper...

Page 6: ...itter all connections must be disconnected individually Resetting the device to the factory setting All connections to radio transmitters are disconnected and parameters are reset to default setting I...

Page 7: ...the factory setting Operating mode Roller shutter Venetian blind Awning Basic setting Roller shutter Roller shutter A rolling shutter or an awning is controlled for which the Fabric stretching functio...

Page 8: ...hannel Priority restraint 0 4 Basic setting 2 Specifies the priority for recalling and removing a scene of type Forced position for the channel Priority wind alarm 0 4 Basic setting 3 Specifies the pr...

Page 9: ...elay contact closed This parameter can be reset to 0 for example after exchanging the load The Reset button is used to reset the counter to 0 The device must be programmed to apply the change Informat...

Page 10: ...ly 12 V for rail mounting Art No NT 1220 REG VDC Master receiver for rail mounting Art No FM FK 32 REG eNet server Art No ENET SERVER 6 4 Warranty We reserve the right to make technical and formal cha...