All of the red LEDs on both push-button sensor modules flash rapidly. 

The button assignment has been applied to the push-button sensor module, and cloning mode is terminated.

•  For further push-button sensor modules, repeat the steps described above.

 

It is not possible to clone devices with different release statuses. Push-button modules register a fault by flashing quickly. 

 

Cloning mode cannot be ended manually. In order to abort an ongoing cloning mode, do not actuate any push-button sensor module for 2 

minutes.

 

If cloning mode was activated at the relay station without any push-button sensor modules being connected, cloning mode is terminated 

automatically after 2 minutes.

Appendix
Technical data

Power supply  

via universal stations 

DC 24 V SELV

Min. current TSM 

approx. 3 mA

Max. current TSM 

approx. 12 mA

Min. current TSM + TSEM 

approx. 3 mA

Max. current TSM + TSEM 

approx. 19 mA

Safety class 

III

Ambient temperature 

+5 ... +45 °C

Storage temperature 

-25 ... +70° C

Connection type 

connection terminal

Cable length 

max. 100 m

Cable type 

J-Y(St)4 2 x 2 x 0.8

Help in case of problems

Push-button sensor module does not respond

Two stations are connected in parallel

Device address of the second station was not converted. 

Change device address

Push-button sensor module does not display the switching state correctly

Switch on status feedback to the station (see relay and dimming station instructions).

Accessories

Universal relay station  

Art. No.: RS 8 REG HE

Universal dimming station Art. No.: UDS 4 REG HE

Warranty

We reserve the right to modify technical and formal characteristics of the product insofar as this supports technical progress.

Our products are under guarantee within the scope of the statutory provisions.

Please send the device, postage paid, to our central Customer Service Centre, with a description of the error.

ALBRECHT JUNG GMBH & CO. KG

Service Centre

Kupferstr. 17-19

44532 Lünen

Germany

 

The CE mark is a free trade symbol intended solely for the authorities, and does not carry any guarantee of properties.

Summary of Contents for 4008 TSM

Page 1: ...red Buttons can be configured corresponding to the cover kit Programming without additional aids Free assignment of the buttons to the channels Red LED as status indicator can be switched off Blue orientation light can be switched off Feedback of switching states on all connected push button sensor modules and sensor modules Up to 4 push button sensor modules with up to 4 push button sensor expans...

Page 2: ...referred Use the double supporting ring 13 For installation to a flush mounted box only countersink the lower screws in the wall e g with bore ø 6 x 10 mm Use supporting ring as template DANGER When installing with 230 V devices under a common cover e g socket outlets there is a danger of electric shock in the event of an error An electric shock can be fatal Do not install any 230 V devices in com...

Page 3: ...ule is operated with a push button sensor expansion module on a single station the push button sensor expan sion module does not have any function in the state as delivered 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Bild3 Button assignment in state as delivered without and with push button sensor expansion module Grouping 1 16 13 16 1 4 1 14 3 16 1 2 14 13 15 3 4 16 1 1 3 9 14 16 6 2 5...

Page 4: ...ns In the state as delivered all channels respond to the central function Preliminary remark to light scene button 3 ⓘ ⓘ Before setting the light scene the station must be set through button 6 Switching several outputs with one button Switching states are assigned to the outputs 4 light scenes per control point are available Preliminary remark to status LED on off button 4 The button next to the r...

Page 5: ...econds LEDs 1 4 6 light up Make additional settings or end programming End programming press and hold button 16 approx 3 seconds Operating level is active Button 2 Setting or changing the central function When assigning the central function button 1 for central ON or button 2 for central OFF is selected then the buttons which should switch the central function It is also possible to assign only ce...

Page 6: ...th channel 1 on and channel 2 off For light scenes the following settings for output 1 apply LED channel 1 LED channel 2 Light ON ON Current status is retained LED flashes slowly ON Switching on brightness LED flashes quickly ON Maximum brightness ON LED flashes quickly Minimum brightness ON OFF off ⓘ ⓘ During display of the light scene the outputs at the stations correspondingly switch with delay...

Page 7: ...normal mode Press micro buttons 12 9 7 9 in sequence All LEDs flash 2x Press micro buttons 12 9 7 9 in sequence once again All LEDs flash 2x The state as delivered has been restored Push button sensor module is ready for operation Installing buttons The buttons are available as a complete button set Individual buttons or the complete button set can be replaced using buttons with sym bols ⓘ ⓘ The i...

Page 8: ...ty class III Ambient temperature 5 45 C Storage temperature 25 70 C Connection type connection terminal Cable length max 100 m Cable type J Y St 4 2 x 2 x 0 8 Help in case of problems Push button sensor module does not respond Two stations are connected in parallel Device address of the second station was not converted Change device address Push button sensor module does not display the switching ...

Reviews: