background image

Page 7

0024015020 12.10.2012

Assigned status LEDs light up.

•  Set the LEDs by pressing the button next to the respective LED.

The LED switches on/off.

Switching the blue orientation light on/off.

•  Press 9 button.

Blue LED switches on/off

All LEDs have been set

•  Back to programming level: press and hold button 16 approx. 3 seconds.

LEDs 1 - 4 light up.

•  End programming level: press and hold button 16.

Operating level is active.

Button 6: Stations

Before light scenes are set, which station is connected with which device address must be entered here. 

 

The push-button sensor module recognises whether one or two stations are connected. When one station is connected, only LED 1 lights 

up.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Bild 8:  Relay station presetting

Presetting:  

Relay station to device addresses 1 and 2

Relay station Dimming 

station

Device address 

1

Button 1 

LED 1

Button 2

LED 2

Device address 

2

Button 5

LED 3

Button 6

LED 4

 

• Press button 6 (

stations

). 

The mode 

Stations

 is active.

• To set the stations, press buttons as indicated in the table. 

Example: 

Device address 1 dimming station: 

button 2

Device address 2 relay station: 

button 5

• Back to programming level: press and hold button 16 approx. 3 seconds.

LEDs 1 - 6 light up.

• End programming level: press and hold button 16.

Operating level is active.

Reset

Reset push-button sensor module to the state as delivered. All settings are overwritten. 

The push-button sensor module is in normal mode.

•  Press micro buttons 12 – 9 – 7 – 9 in sequence.

All LEDs flash 2x

•  Press micro buttons 12 – 9 – 7 – 9 in sequence once again 

All LEDs flash 2x

The state as delivered has been restored.

Push-button sensor module is ready for operation.

Installing buttons

•  The buttons are available as a complete button set. Individual buttons or the complete button set can be replaced using buttons with sym-

bols.

 

The installation spider is not necessary to install the buttons.

 

Place buttons on the device in the right orientation and push briefly to snap in.  

Observe the label TOP.

 

Laser-print buttons at www.jung-lasern.de

Cloning push-button sensor modules

„Cloning“ means transmitting the button assignment of a push-button sensor module to other push-button sensor modules. No operation of the 

stations is possible during an ongoing cloning operation. Only push-button sensor modules with the same release status can be cloned with 

each other.

Several push-button sensor modules are connected to the station. 

Press the MODE and Central Switching Mode buttons of the relay station or the MODE and Prog. button of the dimming station simultane-

ously until the LEDs  , ON/▲ and OFF/▼ flash. Stations and push-button sensor modules are in cloning mode.

All of the red LEDs on the push-button sensor modules are flashing.

•  Press a button on the push-button sensor module being cloned within approx. 2 minutes.

All of the red LEDs on the push-button sensor module flash rapidly.

All of the red LEDs on all of the other the push-button sensor modules continue to flash.

•  Press a button on another push-button sensor module within approx. 2 minutes.

Summary of Contents for 4008 TSM

Page 1: ...red Buttons can be configured corresponding to the cover kit Programming without additional aids Free assignment of the buttons to the channels Red LED as status indicator can be switched off Blue orientation light can be switched off Feedback of switching states on all connected push button sensor modules and sensor modules Up to 4 push button sensor modules with up to 4 push button sensor expans...

Page 2: ...referred Use the double supporting ring 13 For installation to a flush mounted box only countersink the lower screws in the wall e g with bore ø 6 x 10 mm Use supporting ring as template DANGER When installing with 230 V devices under a common cover e g socket outlets there is a danger of electric shock in the event of an error An electric shock can be fatal Do not install any 230 V devices in com...

Page 3: ...ule is operated with a push button sensor expansion module on a single station the push button sensor expan sion module does not have any function in the state as delivered 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Bild3 Button assignment in state as delivered without and with push button sensor expansion module Grouping 1 16 13 16 1 4 1 14 3 16 1 2 14 13 15 3 4 16 1 1 3 9 14 16 6 2 5...

Page 4: ...ns In the state as delivered all channels respond to the central function Preliminary remark to light scene button 3 ⓘ ⓘ Before setting the light scene the station must be set through button 6 Switching several outputs with one button Switching states are assigned to the outputs 4 light scenes per control point are available Preliminary remark to status LED on off button 4 The button next to the r...

Page 5: ...econds LEDs 1 4 6 light up Make additional settings or end programming End programming press and hold button 16 approx 3 seconds Operating level is active Button 2 Setting or changing the central function When assigning the central function button 1 for central ON or button 2 for central OFF is selected then the buttons which should switch the central function It is also possible to assign only ce...

Page 6: ...th channel 1 on and channel 2 off For light scenes the following settings for output 1 apply LED channel 1 LED channel 2 Light ON ON Current status is retained LED flashes slowly ON Switching on brightness LED flashes quickly ON Maximum brightness ON LED flashes quickly Minimum brightness ON OFF off ⓘ ⓘ During display of the light scene the outputs at the stations correspondingly switch with delay...

Page 7: ...normal mode Press micro buttons 12 9 7 9 in sequence All LEDs flash 2x Press micro buttons 12 9 7 9 in sequence once again All LEDs flash 2x The state as delivered has been restored Push button sensor module is ready for operation Installing buttons The buttons are available as a complete button set Individual buttons or the complete button set can be replaced using buttons with sym bols ⓘ ⓘ The i...

Page 8: ...ty class III Ambient temperature 5 45 C Storage temperature 25 70 C Connection type connection terminal Cable length max 100 m Cable type J Y St 4 2 x 2 x 0 8 Help in case of problems Push button sensor module does not respond Two stations are connected in parallel Device address of the second station was not converted Change device address Push button sensor module does not display the switching ...

Reviews: