Connecting Venetian blind insert (1) (see figure 2). Note clampable cable
cross-sections (see figure 3). Optional: Connection of an extension (6). A
mechanical venetian blind push-button or Venetian blind switch can also be
used as an extension instead of the venetian blind insert.
■
Install Venetian blind control in appliance box, terminals must be at the bot-
tom. Recommendation: Use deep appliance box.
■
Switch on mains voltage.
The TEST button also allows activation of the connected motor without a cover, e.g.
to be able to set the end positions of the motor.
■
Press the TEST button for less than 1 second.
Blind/shutter moves in the bottom end position direction.
■
Press button TEST longer than 1 second.
Blind/shutter moves in the upper end position direction.
If the blind/shutter moves in the wrong direction, you can use the reverse func-
tion of the insert.
■
Reverse function: Press the TEST button for more than 10 seconds.
The insert signals successful reversing of the outputs through quick activation
in the Down direction and then in the Up direction. The new direction of travel
is saved to power failure-proof memory.
■
Attach the frame and the cover.
If multiple circuit breakers supply dangerous voltages to the device or load,
couple the circuit breakers or label them with a warning, to ensure disconnec-
tion is guaranteed.
As long as an Up command is active on extension unit input 2 (wind alarm),
the Venetian blind cannot be operated either manually or automatically.
Integrating the device into a group control
The Venetian blind insert can be integrated into a group control (see figure 4), either
for local control (1) or as a master unit (7).
Universal blinds insert