Application

The compli 300 lifting station is manufactured in accordance 

with DIN EN 12050-1 and is approved for the disposal of was

-

tewater from toilets and urinals, and domestic wastewater con

-

taining the usual impurities (as defined in Part 3 of DIN 1986). 

The sewage lifting station can withstand submersion.

Submersion depth: 2 m of water; submersion period: 7 days.

The control unit cannot withstand submersion, but is splash-

proof in accordance with IP 44.

Scope of supply

•   Sewage lifting station with DN 100 inlet with clamp flange

•   Flexible connection with hose clamps for the pressure pipe

•   Slip-on socket pipe, DN 80, for ventilation pipe

•   Plug-in seals for connection of diaphragm hand pump and 

inlet at the side

•   Fixing materials for tank

•   Connection flange for pressure pipe, DN 80

•   Non-return valve, DN 80, for the pressure pipe

Jung Pumpen GmbH • Industriestr. 4-6 • 33803 Steinhagen

XX1

DIN EN 12050-1

Sewage lifting station for buildings, DN 80

See technical data for pumping capacity

Noise emission < 70 dB(A)

1 The first two digits of the pump number indicate the year of production

Electrical connection

Only  qualified  electricians  may  carry  out  electrical 

works to the pump or the plug. 

The relevant standards (such as EN standards), country-specific 

regulations (such as VDE in Germany), and the regulations of 

the local power supply companies must be observed. 

Never put the mains plug in water! If water gets into 

the plug, this can cause malfunctions and damage.

Observe the operating voltage (see the type plate)!

Only  connect  the  pump  to  sockets  that  have  been  installed 

properly in accordance with the regulations and are fitted with 

at least a 10 A (delay) fuse. No additional motor protection is 

required, since the system has an integrated coil thermostat.  

Unacceptably  high  temperatures  and  long  periods  of  conti

-

nuous operation cause the thermostat to shut down the motor. 

After the thermostat has switched off the system, pull out the 

mains  plug  before  remedying  the  fault,  since  the  device  can 

switch itself on again automatically if the power is still connec

-

ted.

The control unit

The compli 300 has a level controller that switches the pump 

on and off depending on the level of the water. An integrated 

alarm system beeps if there is a malfunction, even if this is only 

temporary. In the connector on the circuit board, there is a po

-

tential-free fault indicator contact (5 A/250 V) at terminals 40 

and 41, which allows the alarm signal to be relayed if required.