background image

                                                                                               

 

 

Upward 

 

Non-hook 

 

Specifies serial number of the Product 

 

Batch code 

 

It indicates that the equipment should be sent to the 
special  agencies  according  to  local  regulation  for 
separate collection after its useful life. 

SECTION 3: USING THE PRODUCT 

This section provides the description for operation.         
 

3.1 UNPACKING AND INSPECTING 

Every  attempt  is  made  to  ensure  your  accurate  and  complete  order. 
However, to be sure that your correct order, verifying the contents of the 
box against your packing slip. 
 

The  product  is  designed  for  simplicity  of  operation  and  set-up  and 
requires  minimal  assembly.  The  following  items  are  included  in  your 
box:     

1 (one) Product 

1 (one) Headset 

1 (one) Recording Cable 

1 (one) Operator

s manual 

 

                                                                                               

 

15

 

* Don

t use strong solvent, for example, Acetone. 

* Never use an abrasive such as steel wool or metal polish. 
* Do not allow any liquid to enter the product, and do not immerse any 
parts of the device into and liquids. 
* Avoid pouring liquids on the device while cleaning. 
* Don

t remain any cleaning solution on the surface of the device. 

Wipe  the  surface  of  sensor  of  transducer  with  70%  ethanol  or  alcohol, 
self-air dry or clean with a clean, dry cloth. 

 

4.6 DISINFECTIONS 

Cleaning  the  unit  surface  and  the  transducer  as  the  above  mentioned, 
then  wipe  the  surface  of  transducer  with  70%  ethanol  or  alcohol,  clean 
the transducer surface with a dry, soft cloth. 
* Don

t use low temperature steam sterilization or other way to sterilize. 

* Don

t use high temperature sterilizing process.   

 

4.7 RECYCLING THE BATTERIES 

The batteries are recyclable.    Remove the old battery from the Product 
and follow your local recycling guidelines or Refer to local regulations. 

 

WARNING:

 Irregular treatment of batteries may be result in 

hazards to health and environment. 

 

4.8 AUTHORIZED REPAIR SERVICE 

The Product has no user-serviceable internal components. Try to resolve 
any maintenance issues with the Product by using the Troubleshooting 
Table presented in this chapter. If you are unable to resolve the problem, 
contact Jumper Medical Equipment Co., Limited Service department. 

 

NOTE:

 The warranty will be void upon unauthorized disassembly 

or service of the product. 

 

4.9 CONTACT INFORMATION 

 

Product is manufactured by: 

Summary of Contents for AngelSounds JPD-100S

Page 1: ...PER MEDICAL EQUIPMENT CO LTD 6th Floor No 6 Bldg Nanshui Industry Village 5th Industry Rd Shenzhen 518067 P R China Fetal Heart Detector JPD 100S INSTRUCTION MANUAL Manual Ver 1 0 Issuing Date 2009 11...

Page 2: ...tion book Without written authorization from Jumper Medical Equipment Co Ltd any individual or organization shall not copy modify or translate this book All contents described in this book are consist...

Page 3: ...bsorption and reflection from structures objects and people TABLE OF CONTENTS SECTION 1 INTRODUCTION 1 1 OVERVIEW 1 2 PRODUCT DESCRIPTION 1 1 3 OPERATING PRINCIPLE 1 SECTION 2 SAFETY GUIDANCE 2 2 1 IN...

Page 4: ...retically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in whi...

Page 5: ...ith the controls and how to use the product properly before operating the product CAUTION It should not be used in life supporting or life sustaining applications 1 2 PRODUCT DESCRIPTION The product i...

Page 6: ...l Heart Detector needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided for in the ACCOMPANYING DOCUMENTS Portable and mobile...

Page 7: ...eath CAUTION This alert identifies hazards that may cause minor personal injury product damage or property damage 2 5 SAFETY ALERT DESCRIPTIONS The following is a list of product safety alerts that ap...

Page 8: ...damage to the metal connectors CAUTION Environment of use The product is designed for indoor use Operator must confirm that the environment of use meets the required operating environmental specificat...

Page 9: ...P R China Tel 86 755 26696279 Fax 86 755 26852025 Web site http www jumper medical com Wellkang Ltd Suite B 29Harley Street LONDON W1G9QR U K 5 2 6 SYMBOL DESCRIPTIONS The following symbols may appear...

Page 10: ...leaning solution on the surface of the device Wipe the surface of sensor of transducer with 70 ethanol or alcohol self air dry or clean with a clean dry cloth 4 6 DISINFECTIONS Cleaning the unit surfa...

Page 11: ...ipe the transducer body with soft cloth to remove any remaining coupling gel Clean with soap only 4 5 4 Wring any excess moisture from the cloth before cleaning 4 5 5 Avoid pouring fluids on the devic...

Page 12: ...cables as described in the Section 5 Broken parts cracks damage or extreme wear broken or bent connectors and pins after bending and flexing the cable Replace cable if any abnormalities are found Exa...

Page 13: ...Section 5 for temperature specifications The product requires no calibration 4 3 VISUAL INSPECTION The product and its accessories should be carefully inspected prior to installation once every 12 mon...

Page 14: ...d Generally the site of heart of fetus is 1 3 below of navel line at its earlier stage it then moves upward with increasing of gestational period and the site of heart of fetus will be a little deviat...

Reviews: