background image

70653000T97Z001K000

V2.00/EN/00710320

JUMO LOGOSCREEN 700

Highly-Scalable Paperless Recorder

Brief Instructions

Summary of Contents for LOGOSCREEN 700

Page 1: ...70653000T97Z001K000 V2 00 EN 00710320 JUMO LOGOSCREEN 700 Highly Scalable Paperless Recorder Brief Instructions...

Page 2: ......

Page 3: ...in printed form 13 1 6 2 Device documentation in the form of PDF files 13 1 6 3 Documentation for optional software 14 1 7 Device version 14 2 Description 15 2 1 Brief description 15 2 2 Block diagram...

Page 4: ...the touchscreen 42 5 3 Alarm and event menu 42 5 3 1 Alarm list 43 5 3 2 Event list 44 5 4 Visualization menu display 46 5 4 1 Curve diagram 47 5 4 2 Digital diagram 50 5 4 3 Bar graph 51 5 4 4 Text...

Page 5: ...81 6 1 8 Electrical data 81 6 1 9 Environmental influences 82 6 1 10 Case 82 6 1 11 Approvals and approval marks 83 6 2 Buffer battery replacement 83 6 3 China RoHS 84 6 4 Barcode 85 6 4 1 Batch cont...

Page 6: ...Contents...

Page 7: ...This symbol indicates that components could be destroyed by electrostatic discharge ESD Electro Static Discharge if the respective cautionary measures are not taken Only use the ESD packages intended...

Page 8: ...in the technical documentation provided are prerequisites for risk free mounting installation and startup as well as for ensuring safety when operating the described modules Only qualified personnel...

Page 9: ...controlled manner and prevent static charges due to friction Use only packaging intended specifically for ESD sensitive assemblies components These must consist of conductive plastics No liability ca...

Page 10: ...article in the catalog It is important for communication between the customer and the sales department Fabrication number F Nr The fabrication number indicates among other things the date of manufact...

Page 11: ...inputs outputs 3 Analog 6 analog inputs 5 Option 2 slot 2 a 0 Not used 1 Analog digital 3 analog and 6 digital inputs 1 analog output 2 Analog HI digital 3 analog HI b and 4 digital inputs 4 digital...

Page 12: ...xtra codes one after the other and sep arate them with commas 10 11 a 12 Order code Order example 706530 1 8 1 2 3 4 23 260 887 163 970 1 paperless recorder in the ordered version 1 quick start guide...

Page 13: ...ng manual contains full details on mounting the electrical connection operation parameter ization and the configuration of the device In addition it contains the order details and a list of technical...

Page 14: ...ating principle and the features of the PC Security Manager software PCS ensures that only authorized persons can gain access to the system components device PC software and sign electronic signatures...

Page 15: ...enable the storage of additional batch related information The extra code structured text allows for the creation of individual measurement and re cording applications 2 2 Block diagram Setup program...

Page 16: ...B host interface with cover To remove the cover take hold of the lug and pull it out CAUTION Protection type IP65 front side only with closed USB host interface Protection type IP65 is only guaranteed...

Page 17: ...ferent protection types see technical data Climatic conditions The ambient temperature and the relative humidity at the mounting site must correspond to the technical data Aggressive gases and vapors...

Page 18: ...e mounting Device with terminal cover accessories 6 120 9 144 144 136 138 1 138 1 Distance between panel cut outs Horizontal Vertical Minimum clearance 20 mm 20 mm Recommended distance easier mounting...

Page 19: ...front of the device is not resistant to aggressive acids and lyes scouring agents and clean ing with a pressure cleaner Use of these media can cause damage Only clean the front of the device with sui...

Page 20: ...rve the specifications on the maximum admissible conductor cross section when using the terminal cover see chapter 6 1 8 Electrical data page 81 Step Action 1 Screw the spacer bolt A into the rear wal...

Page 21: ...e device page 19 Device fuse The carrying case is equipped with a replaceable device fuse micro fuse 5 0 A 250 V delayed action according to DIN EN 60127 2 part no 65018001 Any faulty fuses must be re...

Page 22: ...3 Mounting 22 chapter 6 1 10 Case page 82...

Page 23: ...t the potential equalization is correct Electrical safety The device is intended to be installed in control cabinets or plants Ensure that the customer s fuse protection does not exceed 20 A Disconnec...

Page 24: ...N 61010 1 2011 07 for the type test Analog input 1 to Analog input 3 Relay 1 Analog 2 output Ethernet PROFINET interface Analog output 1 RS232 RS485 interface 3510 V Digital 1 to 6 inputs USB host int...

Page 25: ...4 option 4 Slot 3 option 3 Slot 2 option 2 Slot 1 option 1 Connection element and assignment Connection element and assignment 1 USB device interface 4 Relay 1 changeover contact 2 1 2 1 2 2 Ethernet...

Page 26: ...nctions correct ly It is recommended to use the components accessories supplied by the manufacturer CAUTION The device is not suitable for connection to a PoE port power over Ethernet There is the ris...

Page 27: ...7 1 5 Analog input 1 8 1 5 Analog input 2 9 1 5 Analog input 3 13 1 5 Analog input 4 14 1 5 Analog input 5 15 1 5 Analog input 6 19 1 5 Analog input 7 20 1 5 Analog input 8 21 1 5 Analog input 9 RTD t...

Page 28: ...15 1 5 Analog input 4 16 1 5 Analog input 5 17 1 5 Analog input 6 18 1 5 Analog input 16 19 1 5 Analog input 17 20 1 5 Analog input 18 21 1 5 Analog input 7 22 1 5 Analog input 8 23 1 5 Analog input 9...

Page 29: ...2 Digital input 2 6 3 Digital input 3 6 4 Digital input 4 6 5 Digital input 5 6 6 Digital input 6 6 7 24 V 6 8 GND 12 1 Digital input 7 12 2 Digital input 8 12 3 Digital input 9 12 4 Digital input 10...

Page 30: ...gital input 3 6 4 Digital input 4 6 9 24 V 6 10 GND 12 1 Digital input 7 12 2 Digital input 8 12 3 Digital input 9 12 4 Digital input 10 12 9 24 V 12 10 GND 18 1 Digital input 13 18 2 Digital input 14...

Page 31: ...Connection element terminal assignment Analog output DC 0 to 10 V or DC 0 4 to 20 mA configurable Analog digital option order code 1 6 9 Analog output 1 6 10 Analog output 1 12 9 Analog output 2 12 10...

Page 32: ...order code 4 24 1 Digital input output 1 24 2 Digital input output 2 24 3 Digital input output 3 24 4 Digital input output 4 24 5 Digital input output 5 24 6 Digital input output 6 24 7 24 V 24 8 GND...

Page 33: ...Digital input output 16 6 9 24 V 6 10 GND 12 5 Digital input output 17 12 6 Digital input output 18 12 7 Digital input output 19 12 8 Digital input output 20 12 9 24 V 12 10 GND 18 5 Digital input ou...

Page 34: ...open contact NO 24 2 Common contact C 24 3 Normally closed contact NC Relay 3 25 1 Normally open contact NO 25 2 Common contact C 25 3 Normally closed contact NC Relay 4 26 1 Normally open contact NO...

Page 35: ...s a standard feature 2 1 1 TX transmission data 2 1 2 TX transmission data 2 1 3 RX received data 2 1 6 RX received data PROFINET IO device incl Ethernet 2 x RJ45 integrated switch as extra code 2 1 1...

Page 36: ...4 Electrical connection 36...

Page 37: ...y Image after reset also see the Configuration chapter in the operating manual The example shown here is the curve diagram vertical with digital traces View Status bar The status bar consists of three...

Page 38: ...ion of the analog signal e g AI01 for analog input 1 and the analog value Instead of the abbreviation the designation description can also be displayed configuration Navigation bar The navigation bar...

Page 39: ...g toggle to the next active group 5 1 2 LED displays The device is equipped with two LEDs on its front side that display the device status Green LED The green LED power LED flashes after switching on...

Page 40: ...corresponding configuration in the PCS software an electronic signature is required when logging off The signature applies to the entire time period for which the user was logged on Configuration of...

Page 41: ...always create a backup of the data It is also nec essary to select suitable retrieval cycles for the data to prevent data loss The setup program con figuration of the groups provides a guideline valu...

Page 42: ...ration To do so you need to tap the center of the crosshairs shown in the corners of the screen one after another 5 3 Alarm and event menu The alarm and event menu enables you to call up the alarm lis...

Page 43: ...event list An alarm that is present is additionally shown in the status bar and by the red LED View Collective alarm The following collective signals are created and are available in the digital sele...

Page 44: ...ion The events include System messages e g power on configuration change time sync Device alarms malfunctions e g battery discharged data loss input not calibrated Configured alarms Configured events...

Page 45: ...tton is available here which lets you mark the time of a specific event in the memory view with the cursor position 1 Selected event The event is selected by tapping 2 Call up memory view In the memor...

Page 46: ...nd group that should currently be displayed on the device are selected Up to 6 analog channels and 6 digital channels of a group can be shown on one screen View 1 Menu items 3 Scroll up 2 Quit visuali...

Page 47: ...bar 1 Designation pointer of the analog curve 4 Designation pointer of the digital trace 2 Analog curve color change in the event of an alarm 5 Digital trace 3 Auxiliary line configurable 6 Event off...

Page 48: ...s can be a different user to the one who is currently logged on Configuration of the electronic signature see operating manual chapter Configuration only in setup program Electronic signature Example...

Page 49: ...es and digital traces run from right to left The channel infor mation is shown on the right edge of the screen the icons for event and alarm at the top edge of the screen Digital traces and channel in...

Page 50: ...the vertical diagram Accordingly the description also applies to the horizontal di agram Group view Navigation bar Memory view See memory view in the curve diagram chapter 5 4 1 Curve diagram page 47...

Page 51: ...able of an alog signal Call up individual view of analog signal numerical view and bar graph see text image individual view 4 Current analog value color change in the event of an alarm 2 Bar graph of...

Page 52: ...esignation pointer and signal abbrevi ation configurable of the analog signal 4 Digital signal with signal abbreviation configurable and designation pointer 2 Current value of analog signal Displays t...

Page 53: ...a tion configurable of the analog signal 4 Bar graph column diagram of the ana log signal 2 Current value of analog signal 5 Digital signal with signal abbreviation configurable and designation pointe...

Page 54: ...here from analog input 03 4 Limit value for max alarm configurable 2 Current value of analog signal with color change alarm 5 Bar graph column diagram of analog signal with color change alarm 3 Alarm...

Page 55: ...eport and the completed report To create a report it must be activated in the configuration for the relevant group View 1 Designation pointer and signal abbrevi ation configurable of the analog signal...

Page 56: ...ort type configurable here external 4 Completed report 2 Time at which the max value or min value occurred 5 Current ongoing report 3 Time stamp for current report beginning of recording and current t...

Page 57: ...ines of the report are defined and the text for the left column and content of the right column are specified device main menu Configuration Batch Batch line x see also the Configuration chapter in th...

Page 58: ...then this state is displayed through the following symbol 3 Any user who has the corresponding authorization can sign the signature Confirm batches electronic signature right This can be a different u...

Page 59: ...e presentation the zoom factor is computed so as to display the data of the entire batch recording on the screen 1 Designation pointer and signal abbrevi ation configurable of the analog signal 4 Data...

Page 60: ...device For a process screen to be displayed it must be activated configuration parameters in the setup program see oper ating manual chapter Configuration only in setup program Process screens 5 4 9...

Page 61: ...t list of a certain group is displayed mem ory view curve presentation of the completed batch In addition the PCA3000 PC evaluation software can filter the events according to groups Comment with auth...

Page 62: ...n electronic signature for a completed batch only steps 2 to 4 Example of an electronic signature chapter 5 8 Electronic signature page 69 5 5 Text input dialog The text input dialog is used for all f...

Page 63: ...t en tries The text from the list replaces the text in the input box 6 Backspace key The character to the left of the cursor is deleted If multiple characters are select ed they are deleted 3 Shift ke...

Page 64: ...ables you to switch between the various keyboard layouts keyboard as signments e g letters digits non standard characters In the default keyboard layout e g letters each key can be assigned up to 10 c...

Page 65: ...ee the Safe to remove hardware message Flash manager functions Ejecting USB flash drive Function for safely removing the USB flash drive to avoid data loss Writing recording data to USB flash drive An...

Page 66: ...the device This reconfigures the device and data recording is restarted Writing configuration to USB flash drive The configuration data incl the user list is transferred from the device to the USB fla...

Page 67: ...vice depending on the current date here August 04 2016 the current time here 15 00 00 and the selected time period This time can be changed by the user NOTE The recording data that is saved in the dev...

Page 68: ...using the setup program To prevent unauthorized access you can activate a logon procedure with user name and password The web server is configured with the setup program see the operating manual chapt...

Page 69: ...eir sig nature during logoff it applies to the entire time period for which the user was logged on The prerequisites for the electronic signature are the device dependent settings in the PCS software...

Page 70: ...n provide this signature 3 Enter text that describes the meaning of the signature evaluation text using the keyboard Alternatively select text from the text list 1 and if required edit it The possibil...

Page 71: ...71 5 Operation 4 Enter password 5 Confirm process The process can still be aborted here Step Action...

Page 72: ...6 In the report of the completed batch recording press the button 1 to display the signature that was provided The signature here master and the meaning of the signature here batch o k are dis played...

Page 73: ...During signing the time period can only be reduced it can then no longer be expanded Logoff The electronic signature during logoff requires no entry of the user ID as this function is only available f...

Page 74: ...5 Operation 74...

Page 75: ...DIN EN 60584 1 2014 ITS 90 50 to 1768 C 0 1 from 100 C Pt30Rh Pt6Rh B DIN EN 60584 1 2014 ITS 90 0 to 1820 C 0 1 from 600 C W5Re W26Re C ASTM E230M 11 ITS 90 0 to 2315 C 0 1 from 500 C W3Re W25Re D A...

Page 76: ...emperature influence 50 ppm K Smallest measuring span 15 K Sensor line resistance Max 10 per cable for two wire circuit Max 30 per cable for three four wire circuit Measuring range start end Freely pr...

Page 77: ...input 4 to 20 mA a Accuracy refers to the maximum measuring range Small measuring spans lead to reduced linearization accuracy Measuring probe Probe break Short circuit Polarity Thermocouple Is detect...

Page 78: ...tion Counts each positive edge of the input signal Max counting frequency 12 5 kHz Mark to space ratio 30 to 70 high pulse 30 s low pulse 30 s Accuracy for flow measurement 0 5 of measured value ambie...

Page 79: ...racy for flow measurement 0 5 of measured value ambient temperature influence 50 ppm K Output Output signal DC 0 24 V 10 15 galvanically isolated Current at option Analog HI digital Max 40 mA per outp...

Page 80: ...NTP server and Modbus master slave External inputs Via Modbus master slave functionality 120 analog and 120 digital inputs 64 batch texts 10 event texts Max cable length 100 m PROFINET IO device Numbe...

Page 81: ...to DIN EN 61010 1 Measuring category II CAT II to 300 V Protection rating I with internal isolation from SELV Power consumption AC 110 to 240 V 45 VA AC DC 20 to 30 V 30 VA Data backup Internal flash...

Page 82: ...al influences According to DIN EN 60721 3 Storage According to class 1M2 Transport According to class 2M2 Operation According to class 3M3 Electromagnetic compatibility EMC According to DIN EN 61326 1...

Page 83: ...alarm Battery empty If the battery is not changed in time data may be lost The battery must be replaced within 4 weeks after the battery pre alarm has been triggered The bat tery change must be carri...

Page 84: ...FWLRQ 3UR HVVDQVFKOXVV 1XWV 0XWWHU 6FUHZ 6FKUDXEH d 7KLV WDEOH LV SUHSDUHG LQ DFFRUGDQFH ZLWK WKH SURYLVLRQV 6 7 7 QGLFDWH WKH KD DUGRXV VXEVWDQFHV LQ DOO KRPRJHQHRXV PDWHULDOV IRU WKH SDUW LV EHORZ W...

Page 85: ...were drawn up using code 39 6 4 1 Batch control NOTE In order to control batches using the barcode scanner the paperless recorder must have been config ured accordingly The Enter batch texts right is...

Page 86: ...ers incl the characters for the line break can be entered with one scan op eration e g 3 lines of 159 characters each or 10 lines of 47 characters each NOTE The batch control codes BATCH START STOP RE...

Page 87: ...depending on the configuration of the batch line texts loaded via barcode are either reset to the standard text default text Configuration Batch Batch line Delete line Yes or retained Delete line No...

Page 88: ...er as text into the external text variable n n number of variable Example T1 ABC The text ABC is entered into external text variable 1 The entered text is available in the text selector Control charac...

Page 89: ...to be entered Example B2 101 The binary values 1 0 1 are entered as from variable 2 variable 2 1 variable 3 0 variable 4 1 Enter text recipe in batch report Rn enter as comment text e g recipe into t...

Page 90: ...6 Annex 90...

Page 91: ......

Page 92: ...ers Road East Syracuse NY 13057 USA Delivery address Mackenrodtstra e 14 36039 Fulda Germany Phone Fax Email Internet 44 1279 63 55 33 44 1279 62 50 29 sales jumo co uk www jumo co uk Phone Fax Email...

Reviews: