2 Installation specifications for direct mounting

Installation

In measuring point M10 x 1 according to EN 1434 (ball valve, T-piece, adapter screw fitting or heat meter
housing)

1. Place the O-ring onto the assembly aid.

2. Insert into the measuring point and remove the assembly aid.

3. Insert the temperature probe through the O-ring and into the measuring point and tighten the screw

connection, tightening torque 3 to 5 Nm (when installed correctly, the bottom of the hexagon sits on
top of the standard-compliant measuring point).

A new O-ring must be used after each dismounting process.

When mounted, the following applies for the adapter screw fitting set:

Max. operating temperature: 150 °C

Pressure stage: PN16

(1)

O-ring

(2)

Assembly aid

(3)

Temperature probe with screw connection

(4)

Measuring point according to EN 1434/M10 x 1

(3)

(4)

(1)

(2)

Summary of Contents for 902442

Page 1: ...90244261T94Z001K000 V2 00 EN 00669425 Screw connection for temperature probe installation in plastic or brass Installation Instructions...

Page 2: ......

Page 3: ...tents Contents 1 Safety information 4 2 Installation specifications for direct mounting 5 2 1 Plastic screw connection 5 2 2 Brass screw connection 6 3 Installation specifications for immersion sleeve...

Page 4: ...accessible to all users at all times If difficulties occur during startup please do not intervene in any way that could jeopardize your warranty rights Warning symbols CAUTION Risk of burns The instal...

Page 5: ...in the assembly aid to determine the probe installation length Grasp the two halves of the plastic screw directly above the assembly aid and press into the 3 re cesses beads on the temperature probe...

Page 6: ...a loosely placed slotted pin 2 Insert the back of the temperature probe into the assembly aid up to the limit stop 28 mm 3 Press in the slotted pin until it is flush with the hexagonal surface e g usi...

Page 7: ...hrough the O ring and into the measuring point and tighten the screw connection tightening torque 3 to 5 Nm when installed correctly the bottom of the hexagon sits on top of the standard compliant mea...

Page 8: ...able Important Do not mount the plastic screw connection into the recesses beading on the tempera ture probe sleeve 2 Push the plastic screw connection up to the probe tube Screw the probe into the im...

Page 9: ......

Page 10: ...ers Road East Syracuse NY 13057 USA Delivery address Mackenrodtstra e 14 36039 Fulda Germany Phone Fax Email Internet 44 1279 63 55 33 44 1279 62 50 29 sales jumo co uk www jumo co uk Phone Fax Email...

Reviews: