Jumil 3060PD Instruction Manual Download Page 21

21

3060/70 - 3080/90 - 7080/90PD

5 - OCCURRENCES, POSSIBLE CAUSES AND SOLUTIONS

Occurrences

Possible Causes

Note

Solutions

Monitor does not power on

Battery low voltage

Use of multimeter

Change the battery / alternator

Power cables C1 in short-circuit / broken

Replace the power cable C1

Fuse 15A blown out

Change the fuse 15A

Monitor indicates seed 

circuit open / seed motor 

does not spin

Seed motor cable C4 broken

Use of multimeter

Replace the cable C4

Seed motor cable connector improperly 

fitted / connectors pins insulated by dirty 

or bent, misaligned

Visual identification

Clean and check the 

connector sockets and pins

Monitor indicates manure 

circuit open / manure 

motor does not spin

Manure motor cable C4 broken

Use of multimeter

Replace the cable C4

Manure motor cable connector improperly 

fitted / connectors pins insulated by dirty 

or bent, misaligned

Visual identification

Clean and check the 

connector sockets and pins

Application rates do not 

reach the theoretical ideal

Tractor improper hydraulic flow

Enable the motors 

test mode for seed 

and manure check 

the RPM’s theoretical 

x motor in the 

measurement mode > 

test motors RPM

Adjust the tractor hydraulic 

flow / use another tractor

application rate is very 

above the theoretical 

ideal / Encoder is not 

performing the RPM 

reading

Encoder with problems / Support loosen

See if the encoder is 

making the reading 

in the Motors RPM 

test mode / Use the 

multimeter / Visual 

assessment of 

connectors, observe 

in the measurement 

function

Change the Encoder / Tighten 

the Support

Encoder Cable broken (C4 Encoder)

Replace the Cable

Connectors improperly fitted / connectors 

pins insulated by dirty or bent, misaligned

Clean and check the 

connector sockets and pins

Monitor indicates 

controller with no 

contact

The manure and seed 

rate values are not 

displayed

Note: Reason failure of 

communication between 

display and module

Cable C2 or C3 broken

Use of multimeter

Replace the cable C2 or C3

Seed motor Cable connector 

improperly fitted / connectors pins 

insulated by dirty or bent, misaligned

Visual identification

Clean and check the 

connector sockets and 

pins

Module blown out

Visual identification 

LED in the module

Provide the module change

The motors do not run 

with the machine in 

movement

Wheel sensor

 far from the gear / 

Impurities

Cable connector (C6) improperly fitted 

/ Connectors pins insulated by dirty 

or bent, misaligned

Sensor damaged / Cable (C6) broken

Identificação visual 

(LED) / Observe 

se no monitor 

está marcando 

velocidade e o 

ícone do trator está 

ficando verde com 

velocidade

Aproxime o sensor 

da engrenagem / Tire 

impurezas / Reposicione

Limpe e verifique encaixes 

dos conectores e pinos

Troque sensor de roda / 

cabo

Lifting sensor far from the drive

Cable connector (C6) improperly fitted 

/ Connectors pins insulated by dirty 

or bent, misaligned

Sensor damaged / Cable (C6) broken

Visual identification 

(LED) / check in 

the home screen 

if the sensor is 

being activated at 

the moments in 

which the machine 

is being moved up 

and down or when 

it is being driven 

directly

Approach the sensor / 

reposition

Clean and check the 

connector sockets and 

pins

Change the lifting sensor / 

cable

OCCURRENCES

Summary of Contents for 3060PD

Page 1: ......

Page 2: ......

Page 3: ...ts in technology have made the company to develop a great capacity of adaptation due to the demands required by the national and international markets JUMIL is genuinely Brazilian independent and has...

Page 4: ......

Page 5: ...3 3 Manure Configuration and Calibration 10 3 4 Brachiaria Gauging 13 3 5 Pneumatic Springs Configuration 14 3 6 Stop Motors Function 14 3 7 Deposits Volumetric Reference 15 3 8 Seeds Monitoring 15 3...

Page 6: ......

Page 7: ...lic motors and an electronic controller mi nimizing the vibrations in seeders fertilizers making the operation more accurate and efficient Its simple interface enables a quick and dynamic handling You...

Page 8: ...THE EASYTECH Make sure that all the electronic components and cables are properly secured and away from the machine moving parts that might damage them Cables can not be cut twisted or excessively ben...

Page 9: ...incorrect operation can cause physical damage to the system or any component Incorrect system configurations can also cause functional damages due to the equipment malfunctioning 3 1 Easytech System...

Page 10: ...any changes in the type or seed sieve used In the field Rate enter the number of seeds per meter to be distributed per row In Seed disc select the quantity of holes of the disc that is being used In...

Page 11: ...s plastic bags and buckets in the manure distributors and then press to start the procedure The manure deposit volume occurs automatically after its calibration ATTENTION Make sure that the hydraulic...

Page 12: ...all the material and weight it with the assistance of a precision scale Enter the value of the sum generated of all the collected lines in the field Total Collected and inform the quan tity of lines c...

Page 13: ...a dosers opening are adjusted cor rectly according to the desired rate and configured in the display To start the checking procedures for the rate applied to each brachiaria click on the function adju...

Page 14: ...ed during the brachiaria box gauging procedure Repeat the process until the practical value collected matches with the theoretical value informed 3 5 Pneumatic Springs Configuration To adjust the pneu...

Page 15: ...markers level To confirm click on For further information read the item 3 2 Seed Configuration SYMBOL FOR STOP MOTOR STOP MOTOR ACTUATION BUTTON ATTENTION For the perfect operation of these reference...

Page 16: ...n is available only for the combined machines configuration where without leaving the tractor the operator can power off the machine A or the machine B manually in the display to perform the finishing...

Page 17: ...is screen the following information is available to the operator All of worked area Worked hours Excess of speed in relation to the established for the planting 3 11 Machine Under Transportation Warni...

Page 18: ...e and change the working mode state to tests mode the tractor hydraulic system must be powered on in working rotation ATTENTION When selecting the motor you intend to operate make sure that there is n...

Page 19: ...e Gauging return to the work screen and select the button MENU MEASUREMENTS SE EDS MONITOR When the checking is concluded return to the menu test mode seeds monitor and selection the option working mo...

Page 20: ...s displaying failures non compliant with the reality High population error Increases the error tolerance for the seed monitoring rate Lifting sensor Deactivates the lifting sensor inf it is damaged du...

Page 21: ...surement function Change the Encoder Tighten the Support Encoder Cable broken C4 Encoder Replace the Cable Connectors improperly fitted connectors pins insulated by dirty or bent misaligned Clean and...

Page 22: ...sor Cable broken Use of multimeter Change the Sensor Dirty in the sensor Clean the Conductor Machine configuration Machine has 10 lines however identifies 7 Configure OCCURRENCES PNEUMATIC SPRINGS Occ...

Page 23: ......

Page 24: ......

Reviews: