![Jumil 3060PD Instruction Manual Download Page 14](http://html1.mh-extra.com/html/jumil/3060pd/3060pd_instruction-manual_2031067014.webp)
14
Easytech - planting
NOTE:
In this procedure, only the seed transmission shaft
will spin. After the end of the collection time, it will stop by
itself.
After the samples have been collected, weight them
individually and compare the results with the reference on the
display “Doser adjustment to obtain”.
Example: 12.5 grams per row
NOTE:
If the real weight collected is outside the value
informed on the display, change the position of the
brachiaria dosers scale physically in order to obtain the
same technical value informed during the brachiaria box
gauging procedure.
Repeat the process until the practical value
collected matches with the theoretical value informed.
3.5 - Pneumatic Springs Configuration
To adjust the pneumatic springs pressure, in the work screen click on
. Change the desired pressure
using the side cursors
and then click on
to confirm the desired working pressure.
ATTENTION:
The compressor will operate only when necessary.
For that, the relay should be enabled
in the function
and not disabled
.
3.6 - Stop Motors Function
Activate and deactivate motors:
This function
assists the Operator to pause the manure and seed transmission instantaneously. To
release the function Stop Motors, press the button
again.
SYSTEM OPERATION