Jumil 3060PD Instruction Manual Download Page 15

15

3060/70 - 3080/90 - 7080/90PD

In the main screen, press 

 to power on the motors.

3.7 - Deposits Volumetric Reference

The 

Easytech

 system has two volumetric indicators for seed 

 and manure 

 deposits available to 

the operator.

These indicators show the moment in which the operator should pay attention to the seed 

 or manure

 refilling.

To inform how much material is in the deposits, click in the work screen in 

 to select the desired deposit 

and use the side cursors 

 to change the markers level. To confirm, click on 

.

For further information, read the item 3.2 - Seed Configuration.

SYMBOL FOR STOP 

MOTOR

STOP MOTOR ACTUATION  

 BUTTON

ATTENTION:

For the perfect operation of these references, it is extremely important that both the manure calibration 

procedure and the filling in of the field 

Seed in 50 ml (practical counting of the quantity of seeds that a recipient 

of 50 ml can hold), are made correctly.

3.8 - Seeds Monitoring

To enter in the seed monitoring function, click in the work screen in 

.

During the work, if there are any irregularities in the planting lines, a sound warning will be issued highlighting 

in red which line has a problem.

SYSTEM OPERATION

Summary of Contents for 3060PD

Page 1: ......

Page 2: ......

Page 3: ...ts in technology have made the company to develop a great capacity of adaptation due to the demands required by the national and international markets JUMIL is genuinely Brazilian independent and has...

Page 4: ......

Page 5: ...3 3 Manure Configuration and Calibration 10 3 4 Brachiaria Gauging 13 3 5 Pneumatic Springs Configuration 14 3 6 Stop Motors Function 14 3 7 Deposits Volumetric Reference 15 3 8 Seeds Monitoring 15 3...

Page 6: ......

Page 7: ...lic motors and an electronic controller mi nimizing the vibrations in seeders fertilizers making the operation more accurate and efficient Its simple interface enables a quick and dynamic handling You...

Page 8: ...THE EASYTECH Make sure that all the electronic components and cables are properly secured and away from the machine moving parts that might damage them Cables can not be cut twisted or excessively ben...

Page 9: ...incorrect operation can cause physical damage to the system or any component Incorrect system configurations can also cause functional damages due to the equipment malfunctioning 3 1 Easytech System...

Page 10: ...any changes in the type or seed sieve used In the field Rate enter the number of seeds per meter to be distributed per row In Seed disc select the quantity of holes of the disc that is being used In...

Page 11: ...s plastic bags and buckets in the manure distributors and then press to start the procedure The manure deposit volume occurs automatically after its calibration ATTENTION Make sure that the hydraulic...

Page 12: ...all the material and weight it with the assistance of a precision scale Enter the value of the sum generated of all the collected lines in the field Total Collected and inform the quan tity of lines c...

Page 13: ...a dosers opening are adjusted cor rectly according to the desired rate and configured in the display To start the checking procedures for the rate applied to each brachiaria click on the function adju...

Page 14: ...ed during the brachiaria box gauging procedure Repeat the process until the practical value collected matches with the theoretical value informed 3 5 Pneumatic Springs Configuration To adjust the pneu...

Page 15: ...markers level To confirm click on For further information read the item 3 2 Seed Configuration SYMBOL FOR STOP MOTOR STOP MOTOR ACTUATION BUTTON ATTENTION For the perfect operation of these reference...

Page 16: ...n is available only for the combined machines configuration where without leaving the tractor the operator can power off the machine A or the machine B manually in the display to perform the finishing...

Page 17: ...is screen the following information is available to the operator All of worked area Worked hours Excess of speed in relation to the established for the planting 3 11 Machine Under Transportation Warni...

Page 18: ...e and change the working mode state to tests mode the tractor hydraulic system must be powered on in working rotation ATTENTION When selecting the motor you intend to operate make sure that there is n...

Page 19: ...e Gauging return to the work screen and select the button MENU MEASUREMENTS SE EDS MONITOR When the checking is concluded return to the menu test mode seeds monitor and selection the option working mo...

Page 20: ...s displaying failures non compliant with the reality High population error Increases the error tolerance for the seed monitoring rate Lifting sensor Deactivates the lifting sensor inf it is damaged du...

Page 21: ...surement function Change the Encoder Tighten the Support Encoder Cable broken C4 Encoder Replace the Cable Connectors improperly fitted connectors pins insulated by dirty or bent misaligned Clean and...

Page 22: ...sor Cable broken Use of multimeter Change the Sensor Dirty in the sensor Clean the Conductor Machine configuration Machine has 10 lines however identifies 7 Configure OCCURRENCES PNEUMATIC SPRINGS Occ...