EN
33
TECHNICAL DATA
Gas category
13B/P(30)/I3B/P(37)
Gas pressure
28-30 mbar/37 mbar
Gas type
G30, G31
Destination countries
S/N/PL
Injector size
0.58 mm/0.55 mm
Gas heater output
1.5/2.8/4.1 kW
Gas consumption
109/204/298 g/h
Lighter system
Piezo electric
Type of cylinder
Up to 15 kg
Gas hose
Approved in accordance with EN standard
Gas regulator
Approved as per EN16129 (max flow 1.5 kg/h)
Rated voltage, electric heater 230 V ~ 50 Hz
Electric heater output
900/1800 W
Weight
10 kg
DESCRIPTION
1. Gas valve
2. Gas tap
3. Hose
4. Gas regulator
5. Cover plate
6. Gas cylinder
7. Piezoelectric ignition
8. Ignition and minimum
9. Medium
10. Maximum
FIG. 1
ASSEMBLY
NOTE:
Gas cylinder and regulator sold separately.
CONNECTING THE GAS CYLINDER
1. Remove the cover plate on the back of the
gas stove.
FIG. 2
2. Connect the hose to the gas valve and
check that the connection is tight.
3. Connect the other end of the hose to
the gas regulator, and check that the
connection is tight.
FIG. 3
4. Put the gas cylinder in the stove.
5. Fit the cover plate so that the gas cylinder is
held in place.
FIG. 4
6. Open the gas tap before using the stove
and close the tap after use.
LEAKAGE TESTING
WARNING!
Never do a leakage test with a naked flame.
1. Turn off the supply of gas if you suspect a
gas leak.
2. Listen and smell, or use soapy water. Soapy
water forms bubbles if there is any leakage.
3. Tighten the couplings and do a new
leakage test.
4. If the leak persists, turn off the flow of
gas at the regulator and disconnect the
regulator from the gas cylinder.
FIG. 5