Outdoor unit
The outdoor unit consists of two wall brackets,
four vibration dampers and mounting bolts for
masonry and concrete walls. The outdoor unit
has pre-fitted pipe sections with screw fittings
(non-return valves).
Installation kit
The installation kit consists of two gas-filled
pipes, drainage hose, sealant, diffusion tape, 2
pipe insulation sections, cable ties and electrical
cable
with
connector
arrangement
for
connecting the indoor unit to the outdoor unit.
Note that the drainage hose must only be used
for air/air heat pumps and therefore not for
air/water.
NOTE:
Do not remove the plastic plugs on the
pipe sections until the installation of the pipes
has begun.
Holes
Start by drilling with the detection drill to check
that there are no obstacles in the way and that
the hole on the outside will be correct. Holding
the detection drill sideways, feel inside the wall if
there is anything in the way around the detection
drill's hole.
If there is nothing obstructing the detection drill,
the wall bracket can be fitted and the hole
(about 80 mm) drilled. Check the dimension of
the supplied wall bushing.
Set the drill at low speed to prevent a build-up of
heat and the saw teeth becoming "sticky". It is
also a good idea to pre-drill with a 12-15 mm bit
so that any chips in the wall can run out.
Summary of Contents for 416-085
Page 6: ...System A 128 System B 128 INSTALLATION 129 Installing the electric heater 129 ...
Page 9: ...SVENSKA 9 BESKRIVNING Innedel Utedel ...
Page 10: ...SVENSKA 10 MANÖVERPANEL ...
Page 13: ...SVENSKA 13 INSTALLATIONSTYPER DUBBELMANTLAD BEREDARE ...
Page 14: ...SVENSKA 14 DIREKT PÅ ETT VATTENBURET SYSTEM ...
Page 15: ...SVENSKA 15 VIA VÄRMEKÄLLA MED SHUNT ...
Page 16: ...SVENSKA 16 VIA TEKNIK MULTITANK ...
Page 40: ...NORSK 40 BESKRIVELSE Innedel PO Utedel NENTER ...
Page 41: ...NORSK 41 STYREPANEL ...
Page 44: ...NORSK 44 DIREKTE PÅ ET VANNBÅRNT SYSTEM ...
Page 45: ...NORSK 45 VIA VARMEKILDE MED SHUNT ...