ENGLISH
41
Parameter settings
Parameter settings
Code
Description
Range
Standard
Comments
01
Set temperature
15–40 °C
28°C
Adjustable
02
Defrosting cycle
30–90 min
40 min
Depending on model
03
Defrosting – start temperature
-30–0 °C
-7 °C
Depending on model
04
Defrosting – stop temperature
2–30 °C
13°C
Depending on model
05
Defrosting time
1–12 min
8 min
Depending on model
06
Linking
1–2
1 = off
Option
07
Memory function
0–1
1 = auto
Option
08
Circulation pump – operating
setting
0–1
0 = on
Option
09 Temperature
sensitivity
1–5
2
Adjustable
10
Max. difference between
incoming/outgoing water
temperature.
2–20 °C
13°C
Adjustable
11
Pool temperature
-9–90 °C
Actual
12
Outgoing water temperature
-9–90 °C
Actual
13
Circuit temperature
-9–90 °C
Actual
15
Outdoor temperature
-9–90 °C
Actual
START UP
Start up
Check the unit and then start the pump. Check that all the connections for electricity and water have been
made properly.
Check that water does not leak from any of the connections.
Start the unit and re-check that there is no leakage and that water circulates through the system
Check after a period of operation that the air coming out of the pool heat pump is colder than the
outside air.
Set the required temperature on the control panel and allow the unit to run.
The pool heat pump is shut off when the water temperature reaches the required temperature.
When the temperature drops one degree below the set temperature the unit starts automatically.
Moving
In order to move the unit on a flat surface, press down the handle with both hands so that the unit's feet
lift from the ground. The pool heat pump can now be pushed or pulled into the correct position.