ENGLISH
31
International electrical symbols
AC (Alternating Current)
DC (Direct Current)
AC or DC
Earth
Double insulation
Low battery icon
Continuity test
Testing diodes
Capacitance test
Fuse
Warning. See Operating
Instructions.
Conforms to European Union
Standards
TECHNICAL DATA
General specifications
Maximum voltage between any
terminal and earth
1000 V rms.
Fuses
mA input
0.5A/250V fast blow, 5 x 20 mm
20A input
Unfused
Measuring ranges
Manual adjustment
LCD screen
Maximum display: 1999
Measurement frequency
2 or 3 times per second update
Operating temperature
0ºC to 40ºC
Storage
–10ºC to +50ºC
Relative air humidity
≤
75% @ 0ºC - 30ºC
≤
50% @ 31ºC - 40ºC
Altitude (operating)
Max. 2000 m
Altitude (storage)
Max. 10,000 m
Power supply
One 9V battery (NEDA1604,
6F22 or 006P)
Low battery
The display shows " "
Data Hold
The display shows "
"
Negative reading
The display shows "
"
Overload
Display shows "1"
Dimensions (h x w x l)
165 x 80 x 38.3 mm
Weight
Approx. 275 gram (incl. battery)
Specifications: accuracy
Accuracy
±(a% r b digits), guarantee for
one year
Operating temperature
23ºC ±5ºC
Relative air humidity
≤
75%
Temperature coefficient
0.1 x (specified accuracy)/1ºC
DC voltage
Note
Input impedance: 10 M
Ω
.
AC Voltage
Notes
Input impedance: 10 M
Ω
.
Frequency range: 40 Hz – 400 Hz.
Indicates effective value of the sine wave (average value).