9
INSTALLATION
Make sure that the Machine is LEVEL when attaching to the installation (table or pedestal), or if machine is
moved to a new location.
OILING
Referring to Fig. 1, fill the machine at (A) and (B). Oil capacity of class 36200 is 2.5 ounces in the bottom
reservoir and 2.5 ounces in the top reservoir. Use a straight mineral oil, Saybolt viscosity of 90 to 125 seconds
at 100° Fahrenheit (Union Special Spec 175 part no. 28604R). The oil level is checked at gauges (C) and (D).
Maintain oil level between the red lines of these gauges.
This machine is automatically lubricated by a continuously driven rotary pump. Oil flow can be observed
through windows (A) and (B). When installing a new machine or starting a machine that has been idle for
some time, priming may be necessary. Remove plug screws (E), fill holes with recommended oil and replace
screws BEFORE operating. If oil does not flow while machine is running, pump is inoperative.
Remove screw 22733B (F, Fig. 1 inset) to drain oil from the top reservoir. To drain oil from bottom reservoir
remove screw 999-196 (G).
Occasionally, it is necessary to oil the linkage of the presser foot, the knife holder shank (36273A), guide
collar (36273K) and the various links and bearings of the presser foot lifting mechanism and thread tension
release.
Summary of Contents for Union Special 36200 CLASS Series
Page 6: ...6 REPLACEMENT PARTS...
Page 10: ...10 FIG 1 THREADING...
Page 25: ...25 EXPLODED VIEWS...
Page 26: ...26...
Page 28: ...28...
Page 30: ...30...
Page 32: ...32...
Page 34: ...34...
Page 36: ...36...
Page 38: ...38...
Page 40: ...40...
Page 42: ...42...
Page 44: ...44...
Page 46: ...46...
Page 48: ...48...
Page 50: ...50...
Page 52: ...52...
Page 54: ...54...
Page 56: ...56...
Page 60: ...60...
Page 62: ...62...
Page 64: ...64...
Page 68: ......